4.95 based on 202 reviews

🙶 First-time customer with Wake Industrial. The ordering process was completely seamless. The part that we o... 🙷

CDB01.1C-ET-ENS-EN2-NNN-NNN-L2-S-NN-FW Bosch Rexroth Indramat

MPN: R911333403

No Tariffs On US Orders
  • Rated 4.6 (49 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 3-5 Days

Current response time:
5 Minutes 12 Seconds

Preparing your secure checkout page...

The Bosch Rexroth Indramat CDB01.1C-ET-ENS-EN2-NNN-NNN-L2-S-NN-FW is part of the CDB Control Units series and supports two axes. It features two 100Base-TX Ethernet ports, a Multi-Ethernet fieldbus interface, and a Safe Torque Off safety function. The unit has a basic power consumption of 9 W, requires a 24 VDC I/O supply voltage, and provides 12 V and 5 V encoder outputs.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The CDB01.1C-ET-ENS-EN2-NNN-NNN-L2-S-NN-FW belongs to the CDB Control Units series manufactured by Bosch Rexroth Indramat. As a plug-in control section for IndraDrive power modules, it supervises motion tasks, communication, and safety logic inside multi-axis automation assemblies. The unit provides command processing for servo amplifiers and converts fieldbus data into drive-local instructions, allowing synchronized positioning, velocity, and torque regulation on production machinery. This makes it suitable for packaging, handling, and conveyor systems that require coordinated axis control from a compact drive platform.

It can coordinate two mechanical axes through its 2-axis configuration. For network connectivity, the control unit carries Multi-Ethernet hardware that exposes two RJ45 sockets operating under the 100Base-TX standard, and this dual-port topology supports line or ring installations without external switches. Internal consumption is limited to 9 W, so thermal load on the host drive remains low. All onboard I/O electronics are energized from a 24 VDC service rail, and they draw 1.1 A during normal operation. When power is first applied, the device admits an inrush of 6 A that lasts up to 60 ms before falling to steady-state demand. The RS-232 service interface supports transfer rates up to 115 kBaud for service access and diagnostics.

The encoder subsystem offers 12 V power for primary feedback devices and a separate 5 V rail for secondary sensors, so both TTL and HTL encoders can be supported without external adapters. Command relays on the board are rated to switch 24 VDC / 1 A, which suits contactor enable and fault signaling circuits. Drive-integrated functional safety is provided through the Safe Torque Off channel, which is routed to a D-Sub 9 safety connector for direct chaining between axes. This layout reduces external safety wiring and keeps the control section integrated with the surrounding drive hardware.

Axis Count
2
Basic Power Consumption
9 W
Ethernet Ports
2
Ethernet Standard
100Base-TX
Fieldbus Interface
Multi-Ethernet
I/o Supply Current
1.1 A
I/o Supply Voltage
24 VDC
Inrush Current
6 A
Max Inrush Pulse
60 ms
Max Rs232 Baud
115 kBaud
Primary Encoder Supply
12 V
Relay Contact Rating
24 VDC / 1 A
Safety Connector
D-Sub 9
Safety Function
Safe Torque Off
Secondary Encoder Supply
5 V
  • CDB011CETENSEN2NNNNNNL2SNNFW
  • CDB01 1C ET ENS EN2 NNN NNN L2 S NN FW
  • cdb01.1c-et-ens-en2-nnn-nnn-l2-s-nn-fw
  • CDB1.1C-ET-ENS-EN2-NNN-NNN-L2-S-NN-FW

Frequently Asked Questions about CDB01.1C-ET-ENS-EN2-NNN-NNN-L2-S-NN-FW:

Q: How many axes can be managed by the CDB01.1C-ET-ENS-EN2-NNN-NNN-L2-S-NN-FW control unit?

A: This control unit supports up to two axes for simultaneous operation.

Q: How many Ethernet ports does the CDB01.1C-ET-ENS-EN2-NNN-NNN-L2-S-NN-FW provide?

A: The CDB01.1C-ET-ENS-EN2-NNN-NNN-L2-S-NN-FW offers two physical Ethernet ports for multi-network connection.

Q: What Ethernet standard does the CDB01.1C-ET-ENS-EN2-NNN-NNN-L2-S-NN-FW support?

A: The supported Ethernet standard is 100Base-TX for fast industrial communication.

Q: What safety function is included with the CDB01.1C-ET-ENS-EN2-NNN-NNN-L2-S-NN-FW?

A: Safe Torque Off is the integrated safety function available in this model.

Q: What is the input/output supply voltage for the CDB01.1C-ET-ENS-EN2-NNN-NNN-L2-S-NN-FW?

A: The unit requires a 24 VDC supply for powering its input/output system.


Internal Product Review

  • ‘‘The CDB01.1C-ET-ENS-EN2-NNN-NNN-L2-S-NN-FW is a Bosch Rexroth Indramat CDB control unit with a Multi-Ethernet fieldbus interface and 2-axis capability. Dual Ethernet ports with 100Base-TX communication make integration straightforward and give the unit a strong edge in networked automation. Safe Torque Off through a D-Sub 9 safety connector is a valuable feature for control systems with strict safety requirements.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo