CDB01.1C-ET-EN2-EN2-NNN-NNN-L1-S-NN-FW Bosch Rexroth Indramat

MPN: R911326949

No Tariffs On US Orders
  • Rated 4.4 (24 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 3-5 Days

Current response time:
6 Minutes 55 Seconds

Preparing your secure checkout page...

The Bosch Rexroth Indramat CDB01.1C-ET-EN2-EN2-NNN-NNN-L1-S-NN-FW is part of the CDB Control Units series and features an analog output resolution of 19.5 mV per increment. It supports output currents of 500 mA per channel and 1000 mA per group, while its relay contact is rated for 1 A at 30 V DC. The control unit provides a maximum RS232 cable length of 15 meters and supports a baud rate up to 115 kBaud.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The CDB01.1C-ET-EN2-EN2-NNN-NNN-L1-S-NN-FW is a modular drive control unit produced by Bosch Rexroth Indramat for the CDB Control Units series. Mounted on IndraDrive power sections, this board interprets fieldbus commands, supervises feedback devices, and generates setpoint values, allowing precise speed, torque, and position regulation in multi-axis machinery used throughout automated production lines. It is intended for coordinated motion applications where the control section must exchange commands and feedback data with the power stage in real time. This arrangement allows the drive system to manage axis behavior consistently during positioning, synchronized movement, and speed-controlled operation.

Its analog differential output converts internal numerical values to a voltage with a resolution of 19.5 mV/inc, enabling fine adjustment of command signals to external instrumentation. Digital inputs treat anything below 5 V as off and regard 15 V as on, which helps reduce false triggering when long cables are used. The optional EN2 encoder interface draws 6 W, the ET Ethernet module needs 2.2 W, and the L1 safety option consumes 2 W. These values help size the 24 V auxiliary supply for the installed options. When the unit is energized, it momentarily demands an inrush of 6 A, so the upstream protection must tolerate that surge. Each output group can source 1000 mA, while the permitted cable length for the service RS-232 port extends to 15 m without signal conditioning.

For transient events, the supply capacitors charge within 60 ms, and snubber circuits absorb inductive load energy up to 400 mJ. Individual high-side drivers deliver 500 mA per channel, and turn-on verification is possible through a 4 µs probe pulse used by the service interface. Form-C relay contacts can switch 1 A DC at 30 V DC, allowing direct control of brakes or contactors. The asynchronous diagnostic interface reaches 115 kBaud, supporting rapid parameter transfers through the service connection. These electrical characteristics describe the board behavior during startup, switching, and diagnostic access.

Analog Output Resolution
19.5 mV/inc
En2 Module Power
6 W
Et Option Power
2.2 W
Inductive Load Energy
400 mJ
Input Off Level
5 V
Input On Level
15 V
Inrush Current
6 A
Inrush Pulse Width
60 ms
L1 Option Power
2 W
Output Current Per Channel
500 mA
Output Current Per Group
1000 mA
Probe Pulse Width
4 μs
Relay Contact Current
1 A DC
Relay Contact Voltage
30 V DC
Rs232 Cable Length
15 m
Rs232 Max Baud Rate
115 kBaud
  • CDB011CETEN2EN2NNNNNNL1SNNFW
  • CDB01 1C ET EN2 EN2 NNN NNN L1 S NN FW
  • cdb01.1c-et-en2-en2-nnn-nnn-l1-s-nn-fw
  • CDB1.1C-ET-EN2-EN2-NNN-NNN-L1-S-NN-FW

Frequently Asked Questions about CDB01.1C-ET-EN2-EN2-NNN-NNN-L1-S-NN-FW:

Q: What is the analog output resolution of the CDB01.1C-ET-EN2-EN2-NNN-NNN-L1-S-NN-FW?

A: The analog output resolution on this model is 19.5 mV per increment.

Q: What is the inrush current specification for this control unit?

A: The maximum inrush current is 6 A, with a pulse width of 60 ms.

Q: How much output current does each channel support on this unit?

A: Each output channel can deliver up to 500 mA of current.

Q: How much power does the En2 module consume?

A: The En2 module operates at a power consumption of 6 W.

Q: What are the RS232 cable length and maximum baud rate for this product?

A: The RS232 cable can be up to 15 meters long and supports a maximum baud rate of 115 kBaud.


Internal Product Review

  • ‘‘The CDB01.1C-ET-EN2-EN2-NNN-NNN-L1-S-NN-FW is a Bosch Rexroth Indramat CDB control unit that feels well suited for precise machine control and clean system integration. RS232 communication support up to 115 kBaud with a 15 m cable length gives this unit excellent serviceability in cabinet installations. Output capacity of 500 mA per channel and 1000 mA per group makes this control unit a strong performer for dependable I/O handling.’’