The Bosch Rexroth Indramat BTA20.3-NE-DC-BA-BS is part of the BTA20 Machine Control Boards series and features 8 input and 8 output channels at 24 volts, with each output supporting up to 200 milliamps. This machine control board is equipped with a 5 V bus output at 50 milliamps, two E-stop circuits, and a protection rating of IP65 on the front panel. It includes one Interbus input and output, operates at 500 kbaud, and supports up to four devices with a Bt bus length of 50 meters.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The BTA20.3-NE-DC-BA-BS control board is manufactured by Bosch Rexroth Indramat and belongs to the BTA20 Machine Control Boards series. Installed in a cabinet door or operator panel, it provides the interface between field wiring and central motion controllers in automated assembly, packaging, and material-handling stations. The unit combines safety functions, discrete I/O, and bus routing on one printed circuit assembly so that sensors, emergency stops, and decentralized drives can be supervised from a single node within an industrial automation network.

The board has 8 digital inputs at 24 V for proximity switches, and it also provides eight 24 V outputs for indicator lamps or small relays. Each output channel is limited to 200 mA, so the connected load must remain within that current range. For logic expansion or sensor power, the board supplies a regulated 5 V rail with an available output of 50 mA for external devices such as encoder modules. The safety section uses 2 hard-wired E-stop circuits that remove power from actuators when triggered. The sealed front face has an IP65 rating, which helps protect the keypad and LEDs from dust and low-pressure water jets. A keyed selector switch provides three distinct positions for setup, automatic, and service modes.

For inter-panel expansion, the board includes a Bt local bus that can span 50 m and support up to 4 slave devices, enabling stacked configurations without added wiring harnesses. The built-in Interbus interface exchanges cyclic data at 500 kbaud and transfers a total payload of 48 bits per scan, with one input register and one output register mapped to the field controllers at that rate. Single RS-422 input and output channels provide point-to-point diagnostics or recipe loading, complementing the Interbus connection when deterministic peer links are required. A dedicated 24 V input for the key switch helps ensure that operating mode changes are reported reliably to the supervisory PLC.

24 V Input Count
8
24 V Output Count
8
24 V Output Current
200 mA
5 V Bus Output
50 mA
Bt Bus Length
50 m
Bt Bus Max Devices
4
E-stop Circuits
2
Interbus Baud Rate
500 kbaud
Interbus Data Width
48 bits
Interbus Inputs
1
Interbus Outputs
1
Key Switch Positions
3
Protection Rating
IP65 (Front Panel)
Rs422 Inputs
1
Rs422 Outputs
1
  • BTA 20.3-NE-DC-BA-BS
  • BTA-20.3-NE-DC-BA-BS
  • BTA20-3-NE-DC-BA-BS
  • BTA20.3 NE DC BA BS
  • BTA203NEDCBABS
  • BTA2O.3-NE-DC-BA-BS

Frequently Asked Questions about BTA20.3-NE-DC-BA-BS:

Q: How many 24 V input channels does the BTA20.3-NE-DC-BA-BS provide?

A: This board supports eight separate 24 V inputs for digital control signals.

Q: What is the maximum output current per channel for the 24 V outputs on this board?

A: The 24 V output current capacity for each output channel is 200 mA.

Q: What is the front panel protection rating of the BTA20.3-NE-DC-BA-BS control board?

A: The BTA20.3-NE-DC-BA-BS offers a front panel protection rating of IP65 against dust and water.

Q: How many devices can the Bt Bus handle and what is its maximum length on this model?

A: It supports up to four devices on the Bt Bus with a maximum total bus length of 50 meters.

Q: How many key switch positions does the BTA20.3-NE-DC-BA-BS feature?

A: There are three selectable key switch positions available on this board for operational control.


Internal Product Review

  • ‘‘The BTA20.3-NE-DC-BA-BS is a Bosch Rexroth Indramat machine control board with 8 x 24 V inputs and 8 x 24 V outputs. Interbus communication at 500 kbaud with a 48-bit data width supports fast, orderly exchange for machine-level control. An IP65 front panel and 2 E-stop circuits make the board a strong choice for dependable operator-side integration.’’