The Bosch Rexroth Indramat BTA20.3-NA-SP-VA-BS is part of the BTA20 Machine Control Boards series and offers 8 external inputs and 8 external outputs. It features a 24 VDC nominal supply, a 200 mA output current, and supports a bus data width of 48 bits. The board provides IP65 protection at the front, IP20 housing protection, and has two E-stop circuits and three enabling circuits.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The BTA20.3-NA-SP-VA-BS module is a machine control board produced by Bosch Rexroth Indramat within the BTA20 Machine Control Boards series. Deployed inside operator stations or cabinet racks, it relays safety, fieldbus, and manual override information between sensors, drives, and higher-level PLCs. In automated lines, the board coordinates emergency-stop chains and runtime interlocks so that motion axes and tooling respond predictably to operator commands.

For primary power, the board draws a nominal supply of 24 VDC, and an auxiliary regulator provides up to 200 mA at 24 V for local sensors or indicator lamps. Process data moves across a 48-bit backplane, and a width of 48 bits allows simultaneous transfer of position, status, and checksum words without serialization delays. When linked to Interbus, the communication layer is clocked at 500 kbaud, matching the timing budget of adjacent drive controllers. Eight digital sensing channels accept limit switches, light curtains, or barcode readers, and the board supports 8 external inputs. The card also provides one Btc06.2 diagnostic port, two internal emergency-stop circuits, three enabling circuits, and eight transistorized external outputs for lamp stacks or relays.

The front panel carries an IP65 rating so washdown or dusty environments cannot foul the membrane keys, while the side and rear areas are ventilated to the enclosure standard of IP20. Sixteen coded selector points give operators 16 override positions for jog, feed, or maintenance modes without reprogramming the PLC. If long cable runs are required, the onboard converter changes signaling from RS232 to RS422/485 so noise immunity is preserved on multi-drop segments. This helps the board maintain dependable communication in installations with longer wiring paths and electrically noisy surroundings.

24 V Output Current
200 mA
Btc06.2 Port
1
Bus Data Width
48 bits
E-stop Circuits
2
Enabling Circuits
3
External Inputs
8
External Outputs
8
Front Protection
IP65
Housing Protection
IP20
Interbus Baud Rate
500 kbaud
Nominal Supply
24 VDC
Override Positions
16
Signal Conversion
RS232 to RS422/485
  • BTA 20.3-NA-SP-VA-BS
  • BTA-20.3-NA-SP-VA-BS
  • BTA20-3-NA-SP-VA-BS
  • BTA20.3 NA SP VA BS
  • BTA203NASPVABS
  • BTA2O.3-NA-SP-VA-BS

Frequently Asked Questions about BTA20.3-NA-SP-VA-BS:

Q: What is the bus data width of the BTA20.3-NA-SP-VA-BS control board?

A: The BTA20.3-NA-SP-VA-BS control board features a bus data width of 48 bits, ensuring broad data handling capability.

Q: What are the protection ratings for the BTA20.3-NA-SP-VA-BS board?

A: This model provides protection ratings of IP65 for the front and IP20 for the housing.

Q: What is the nominal supply voltage for the BTA20.3-NA-SP-VA-BS?

A: The nominal supply required for this control board is 24 VDC.

Q: How many external inputs and outputs does the BTA20.3-NA-SP-VA-BS have?

A: There are 8 external input and 8 external output connections available on this board.

Q: What type of signal conversion does the BTA20.3-NA-SP-VA-BS support?

A: The BTA20.3-NA-SP-VA-BS can convert signals from RS232 to RS422/485.


Internal Product Review

  • ‘‘The BTA20.3-NA-SP-VA-BS is a Bosch Rexroth Indramat machine control board with IP65 front protection and IP20 housing protection. RS232 to RS422/485 signal conversion and 500 kbaud Interbus communication support clean integration into established control architectures. Three enabling circuits and two E-stop circuits make the board a strong choice for safety-focused machine control.’’