2AD164C-B05OA1-BS06-C2N1

MPN: R911295985

No Tariffs On US Orders
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The 2AD164C-B05OA1-BS06-C2N1 is a robust AC synchronous servo motor with a rated power of 5.5 kW and flange mounting. Designed by Bosch Rexroth Indramat for the 2AD 3-Phase Induction Motors series, it features digital servo feedback and external fan cooling. With IP65 protection and a weight of approximately 40 kg, it ensures reliability.

Quote Request Form:

Warranty
Wake Industrial Warranty
To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The 2AD164C-B05OA1-BS06-C2N1 asynchronous AC motor delivered with Bosch Rexroth Indramat’s expertise supports continuous standstill torque up to its derating speed for S1 operation. This motor features Class F insulation. The product’s drive end comprises its plain shaft surrounded by the shaft sealing. This device’s blower directs its air currents from its Side B towards Side A. The unit-related readymade cables have an IP 67 protection class. It supports no structural changes or modifications. This motor’s nominal torque as well as power are determined per DIN VDE 0530 specifications.

The product’s blower is connected with its power supply through a power switch and blower cables. This device’s temperature sensors are always present in pairs. The unit’s pin assignments for the encoder connection depend on the type of encoder. Its cables and plugs have to be ordered as separate items. This motor’s flange socket has an external thread. The product’s lifting and transport can be simplified by using eye bolts. This device’s bolted connections must withstand its weight. The unit’s connections must be checked for their precision and proper fit before mounting. It must be confirmed that the EMC requirements are met if third-party cables are used.

This asynchronous AC motor’s terminal box encompasses a cover, a PE connection, a gasket, a cable entry, a terminal strip, and a U-V-W power connection. The product’s union nut present in the flange socket must not be tightened using tools. This device’s dismantling requires the switching off the drive controller, blower, and installation machine. The unit’s commissioning is carried out as part of commissioning the whole drive system. Its mechanical connections should be disconnected after ensuring that it doesn’t fall off.

Cooling Type
External Fan Cooling (Type B05O)
Feedback Type
Digital Servo Feedback (BS06)
Frame Size
2AD, Size 164
Motor Type
AC Synchronous Servo Motor
Mounting Type
Flange Mount
Protection Class
IP65
Rated Current
17.3 A
Rated Power
5.5 kW
Rated Speed
1500 rpm
Rated Voltage
353 V
Thermal Class
F
Weight
Approximately 40 kg
  • 2AD164C B05OA1 BS06 C2N1
  • 2AD164CB05OA1BS06C2N1
  • 2AD164C-B050A1-BS06-C2N1
  • 2AD164C-BO5OA1-BSO6-C2N1
  • 2AD164C-805OA1-8S06-C2N1
  • 2AD164C-8O5OA1-8SO6-C2N1
  • 2AD164CB050A1BS06C2N1
  • 2AD164CBO5OA1BSO6C2N1

Frequently Asked Questions about 2AD164C-B05OA1-BS06-C2N1:

Q: Why does the 2AD164C-B05OA1-BS06-C2N1 motor have a very high housing temperature?

A: The 2AD164C-B05OA1-BS06-C2N1 motor has a very high housing temperature because its original parameters have been changed or the failure of its blower system.

Q: How should the union nut in the flange socket of the 2AD164C-B05OA1-BS06-C2N1 motor be tightened?

A: The union nut in the flange socket of the 2AD164C-B05OA1-BS06-C2N1 motor should be tightened by hand.

Q: When does the 2AD164C-B05OA1-BS06-C2N1 motor deliver maintenance-free operation?

A: The 2AD164C-B05OA1-BS06-C2N1 motor delivers maintenance-free operation when it is run within its specified operating conditions.

Q: What kind of winding connection does the 2AD164C-B05OA1-BS06-C2N1 motor have?

A: The 2AD164C-B05OA1-BS06-C2N1 motor has a star winding connection.

Q: What check should be done to the installation machine before doing any repair work on the 2AD164C-B05OA1-BS06-C2N1 motor?

A: The installation machine should be secured against restarting and unauthorized use before doing any repair work on the 2AD164C-B05OA1-BS06-C2N1 motor.


Internal Product Review

  • ‘‘The 2AD164C-B05OA1-BS06-C2N1 motor has reduced grease lifetime with vertical installation. It portrays Class F insulation. The motor has a dedicated flange socket for the feedback connection. ’’