2AD160B-B35LA2-BS03/S019

MPN: R911233267

No Tariffs On US Orders
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat 2AD160B-B35LA2-BS03/S019 is part of the 2AD 3-Phase Induction Motors series, featuring a robust IP65 protection class and flange and foot mounting. This motor delivers a rated power of 14.5 kW with a rated speed of 1500 rpm. It utilizes an axial blower cooling system and keyed shaft with a shaft seal.

Quote Request Form:

Warranty
Wake Industrial Warranty
To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

Introduced by Bosch Rexroth Indramat, the 2AD160B-B35LA2-BS03/S019 asynchronous AC motor houses a flange socket that can be installed and removed using special tools. This motor’s spare temperature sensor can be connected only after switching off the installation machine and the drive controller and securing them against unauthorized use or restart. The product shuts down automatically when the sensor senses a housing temperature of 155 °C. This device is likely to have a high housing temperature if the original motor parameters or processing cycle are changed. The unit’s drive controller displays the fault and diagnostics messages related to the motor’s thermistor and encoder. Its maintenance is not allowed when its machine is running.

This motor’s maintenance measures must be recorded in the machine maintenance plan. The product’s deactivation has to be done as per the steps in its manual. This device’s power connection includes the connection of its temperature sensor. The unit’s blower is connected through a dedicated terminal box. Its blower encompasses a screen that shows the direction of the air flow.

The motor’s flange socket comprises a union nut that must be tightened manually. The product’s electrical connections are done only after its mechanical mounting has been done. This device’s protective sleeves have to be removed during its mounting process. The unit needs a check to be done for damage before its installation. Its components are prone to damage if repeated high-voltage tests are carried out on the motor. The asynchronous AC motor’s operation can be done only when the specified minimum volume of air is drawn through the blower over the housing of the motor.

Cooling Type
Axial Blower
Feedback Device
High-resolution motor feedback
Motor Length Code
B
Motor Size Code
160
Motor Type
Asynchronous
Mounting
Flange and foot mounting
Output Shaft
Keyed shaft with shaft seal
Power Connection Direction
To Side A
Power Connection Position
Left (View from front towards shaft)
Power Connection Type
Terminal Box
Rated Power
14.5 kW
Rated Speed
1500 rpm
Rated Torque
92 Nm
Rated Voltage
380-480 V
Winding Code
BS
  • 2AD160B B35LA2 BS03/S019
  • 2AD160BB35LA2BS03/S019
  • 2AD160B-B35LA2-BS03/S019
  • 2AD16OB-B35LA2-BSO3/SO19
  • 2AD1608-835LA2-8S03/S019
  • 2AD16O8-835LA2-8SO3/SO19
  • 2AD16OBB35LA2BSO3/SO19

Frequently Asked Questions about 2AD160B-B35LA2-BS03/S019:

Q: How are the blower and power connections of the 2AD160B-B35LA2-BS03/S019 motor established?

A: The blower and power connections of the 2AD160B-B35LA2-BS03/S019 motor are established using terminal boxes.

Q: Can the 2AD160B-B35LA2-BS03/S019 motor be used in explosion-hazardous areas?

A: No, the 2AD160B-B35LA2-BS03/S019 motor cannot be used in explosion-hazardous areas as its parts do not have explosion protection.

Q: What is the mechanical lifetime of the bearing of the 2AD160B-B35LA2-BS03/S019 motor?

A: The mechanical lifetime of the bearing of the 2AD160B-B35LA2-BS03/S019 motor is 20,000 hours.

Q: What is the repeatability of the encoder of the 2AD160B-B35LA2-BS03/S019 motor?

A: The repeatability of the encoder of the 2AD160B-B35LA2-BS03/S019 motor is its relative accuracy.

Q: What is the minimum distance required between the blower screen of the 2AD160B-B35LA2-BS03/S019 motor and the installation machine?

A: The minimum distance required between the blower screen of the 2AD160B-B35LA2-BS03/S019 motor and the installation machine is 80 mm.


Internal Product Review

  • ‘‘The 2AD160B-B35LA2-BS03/S019 motor comes with the power terminal positioned to its left. It supports flange and foot mounting options. The motor can be operated like a rotary main-spindle motor.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo