The 2AD134C-B05OB1-DS06-D2N1 motor boasts a motor frame size of 134 mm, IP65 protection, and a rated power output of 6 kW. From the 2AD 3-Phase Induction Motors series by Bosch Rexroth Indramat, it features a flange mounting design and a robust digital servo feedback system with IndraDyn S technology.

Quote Request Form:

Warranty
Wake Industrial Warranty
To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The Bosch Rexroth Indramat’s manufactured 2AD134C-B05OB1-DS06-D2N1 3-Phase Induction Motor is used in industries to provide a wide range of automation tasks. This motor has a nominal power rating of 18 kW for high-energy output, ideal for tasks that require consistent performance within full-load conditions.

The nominal current of 54.4 Veff is specifically matched with this motor's winding and thermal rating to provide efficient electrical input with minimal energy loss within prolonged operational cycles. This motor runs at a base speed of 1500 min⁻¹ to offer stable rotational output for processes that require constant-speed operation. The built-in DS-type winding structure improves this motor’s stator thermal and magnetic attributes, thus reducing internal resistance and enhancing operational stability. This induction motor’s axial blower cooling mode utilizes forced air flow through the housing to allow quick heat dissipation that is generated and minimize thermal buildup. A key thermal specification of this motor is its 50-minute thermal time constant, which sustains elevated operating temperatures for extended periods without risking insulation degradation. The output shaft of this induction motor is constructed using a shaft sealing ring to keep dust and liquids out, and the whole key-balanced shaft provides smooth torque transfer.

The rotor inertia of the 2AD134C-B05OB1-DS06-D2N1 motor is 0.076 kgm², which enables it for controlled acceleration and deceleration under high-cycle start-stop applications. With a weight of 115 kg, the housing of this induction motor is designed for rigid mounting and vibration resistance in heavy industrial installations. The 10 mm² minimum cable connection cross-section provides this motor with sufficient current-carrying capacity and a safe electrical connection. The storage temperature range of the 2AD134C-B05OB1-DS06-D2N1 induction motor is between -20°C and +80°C to ensure stability during non-operational periods.

Base motor speed
1500 min-1
Bearings type
Standard
Cooling mode
Axial blower
Insulation classification DIN VDE 0530 Teil 1
F
Mass
115 kg
Min. connection cross-section of cable
10 mm2
Nominal current
54.4 Veff
Nominal power
18 kW
Output shaft
With shaft sealing ring, with whole key balanced
Permissible storage temperature range
-20° C to +80° C
Rotor inertia
0.076 kgm2
Thermal time constant
50 min
Winding type
DS
  • 2AD134C B05OB1 DS06 D2N1
  • 2AD134CB05OB1DS06D2N1
  • 2AD134C-B050B1-DS06-D2N1
  • 2AD134C-BO5OB1-DSO6-D2N1
  • 2AD134C-805O81-DS06-D2N1
  • 2AD134C-8O5O81-DSO6-D2N1
  • 2AD134CB050B1DS06D2N1
  • 2AD134CBO5OB1DSO6D2N1

Frequently Asked Questions about 2AD134C-B05OB1-DS06-D2N1:

Q: What benefit does a whole key balanced shaft provide in torque applications?

A: It ensures uniform torque distribution across the shaft during load transfer. This reduces vibration and misalignment issues.

Q: Why is the shaft sealing ring important in the 2AD134C-B05OB1-DS06-D2N1 motor?

A: It prevents contaminants from entering the motor housing. This helps maintain lubrication quality and extends component lifespan.

Q: How does the DS winding type improve motor efficiency?

A: DS winding reduces internal resistance and enhances heat dissipation, improving overall energy conversion. This leads to better performance under thermal and load stress conditions.

Q: Why is the rotor inertia of 0.076 kgm² significant for the 2AD134C-B05OB1-DS06-D2N1 motor?

A: It enables the motor to start and stop quickly without destabilizing motion. This is critical in fast-response automation systems.

Q: How does axial blower cooling support high-duty cycles?

A: It forces air over the motor surface, removing heat rapidly. This allows continuous operation without overheating.


Internal Product Review

  • ‘‘The 2AD 3-Phase Induction Motor with product code 2AD134C-B05OB1-DS06-D2N1 offers a base speed of 1500 min⁻¹ and 0.076 kgm² rotor inertia, ensuring responsive acceleration. Its axial blower cooling and Class F insulation support prolonged duty cycles. Its 10 mm² cable requirement secures stable electrical connectivity in industrial environments.’’