4.95 based on 202 reviews

🙶 Wake was very helpful in getting us a servo motor and drive for our tube mill line. This was the first tim... 🙷

IP2302-B528-0000 Beckhoff

Ask for Availability
No Hidden Fees Rush or Credit Card
No Tariffs On US Orders

Internal Product Review

The IP2302-B528-0000 is a Beckhoff IP Compact Box I/O module with 4 inputs and 4 outputs. DeviceNet with an integrated tee-connector and control/fieldbus isolation support clean network integration and dependable signal handling. Rated for 24 VDC with 0.5 A output current per channel, the unit stands out as an efficient distributed I/O solution.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The IP2302-B528-0000 is a compact digital I/O module produced by Beckhoff for its IP Compact Box Units series. Housed in a sealed field enclosure, the unit brings sixteen discrete lines directly to a machine chassis and maps them to a controller over a single bus cable. This design lets an automation system collect sensor states and drive actuators at the installation point, reducing cabinet wiring and simplifying decentralized layouts common in conveyors, packaging machines, and assembly stations.

The module communicates through a DeviceNet node that already contains a tee connector, so it can be inserted anywhere along the trunk without additional fittings. All channels share a rated load of 24 VDC, and the process image occupies exactly 4 inputs and 4 outputs in the PLC memory. Each output can source up to 0.5 A per channel, while each input draws only 6 mA, allowing tight grouping on common supply rails. Load circuits are protected by an internal limit of 20 mA per input and by per-channel sensor supply paths that match the 0.5 A capacity of the outputs.

A separate M8 power feed connector delivers the field voltage, and the module passes that voltage to downstream devices through an identical M8 socket, maintaining daisy-chain power distribution without extra terminal blocks. Signal quality is maintained with a debouncing filter of 3.0 ms, and a short-circuit threshold of 1.5 A disables an affected channel until the fault clears. Galvanic isolation between the control and fieldbus circuits prevents back-feed from inductive loads, and all inputs conform to EN 61131-2 Type 2, ensuring consistent switching levels across equipment from different vendors. Threaded M12 connectors provide a vibration-resistant path for the field conductors, while a four-pin M8 socket on the opposite end supports downstream bus expansion without changing node addresses.

Bus Interface
DeviceNet with integrated tee-connector
Control/fieldbus Isolation
Yes
Downstream Connector
1 x M8 socket, 4-pin
Input Current
6 mA
Input Filter
3.0 ms
Input Standard
EN61131-2 Type 2
Load Voltage Current
20 mA per channel
Number Of Inputs
4
Number Of Outputs
4
Output Current
0.5 A per channel
Power Feed Connector
1 x M8 connector, 4-pin
Process Image
4 bits input, 4 bits output
Rated Load Voltage
24 VDC
Sensor Supply
0.5 A per channel
Short-circuit Current
1.5 A
Signal Connection
M12 bolted connection

Frequently Asked Questions about IP2302-B528-0000:

Q: How many digital inputs are available on the IP2302-B528-0000 box unit?

A: The IP2302-B528-0000 features 4 digital inputs in accordance with EN61131-2 Type 2.

Q: What is the per-channel output current capability of the IP2302-B528-0000?

A: This model provides a maximum output current of 0.5 A per channel.

Q: What type of bus interface is equipped on the IP2302-B528-0000 unit?

A: A DeviceNet bus interface with integrated tee-connector is used for connecting the IP2302-B528-0000 to the network.

Q: What is the rated load voltage for the IP2302-B528-0000?

A: The rated load voltage for this unit is 24 VDC, supporting industrial power requirements.

Q: Does the IP2302-B528-0000 offer isolation between control signals and the fieldbus interface?

A: The IP2302-B528-0000 provides control and fieldbus isolation to enhance operational safety and data integrity.

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo