IP1002-B518 Beckhoff
Wake Industrial LLC is not an authorized distributor of this product.
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Beckhoff IP1002-B518 is part of the IP Compact Box Units series and comes with 8 digital inputs and an integrated tee-connector bus connection. It supports a nominal input voltage of 24 VDC, a sensor supply of 0.5 A per channel, and is rated for IP65/IP66/IP67 protection classes. The device uses a CANopen fieldbus system and has control and fieldbus isolation.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The IP1002-B518 is a distributed I/O module produced by Beckhoff within the IP Compact Box Units series. Intended for decentralized installation, the device captures on-machine sensor states and transfers them to a central PLC through the CANopen fieldbus. It serves industrial automation tasks that require compact, sealed input nodes near actuators and sensors. The sealed housing permits mounting outside control cabinets, and relocating the input circuitry to the field shortens wiring runs between sensors and the controller. This arrangement is useful on conveyors, handling stations, and compact machine sections where cabinet space is limited and field devices are spread across the machine frame.
Each of the 8 digital inputs follows the EN 61131-2 Type 2 specification and is energized from a 24 VDC nominal supply. When a sensor switches, only 6 mA of current is drawn, which helps limit loading on the upstream sensor source. A built-in 3.0 ms filter suppresses contact bounce so transient edges are less likely to appear in the controller image during switching events. The IP65/IP66/IP67 protection rating shields the electronics from dust and water exposure, allowing the module to be mounted directly on machinery in dirty or washdown-prone areas. That combination suits standard proximity switches, photoelectric sensors, and other 24 V input devices commonly used in automated equipment.
Communication to the network is handled by the CANopen protocol, and the molded bus interface uses an Integrated Tee-Connector so modules can be added without extra junctions. Power for downstream devices can be forwarded through a 1 x M8 socket, 4-pin, while the upstream supply enters through a separate M8 connector. Inputs are connected through an M12 screw-in plug and are galvanically isolated from the fieldbus, which helps reduce ground-loop interference between the control level and field wiring. This layout supports straightforward field wiring and keeps auxiliary distribution close to the connected sensors. The process image carries eight bits of input data, and the sensor supply can provide up to 0.5 A per channel. The unit is not programmable, which helps keep operation consistent in fixed I/O tasks.
Frequently Asked Questions about IP1002-B518:
Q: How many digital inputs does the Beckhoff IP1002-B518 provide?
A: The IP1002-B518 supports up to 8 digital inputs for signal acquisition.
Q: What is the nominal input voltage required for the IP1002-B518?
A: This unit is designed for use with a 24 VDC nominal input voltage.
Q: What type of bus connection does the IP1002-B518 utilize?
A: The IP1002-B518 features an integrated tee-connector for simple bus connection.
Q: What protection class does the IP1002-B518 compact box unit have?
A: It is rated for IP65, IP66, and IP67, providing protection against dust and water.
Q: Which fieldbus system is implemented in the IP1002-B518?
A: The fieldbus system used in this unit is CANopen for communication.