4.95 based on 202 reviews

🙶 We have never had a problem in the almost 20 years we have dealt with Wake. We would recommend them to any... 🙷

IE3312-B520-0000 Beckhoff

Ask for Availability

Preparing your secure checkout page...

The Beckhoff IE3312-B520-0000 is part of the IE Extension Box Units series and features four analog inputs with a channel-to-control isolation of 500 V. This unit supports DeviceNet fieldbus, offers IP65/IP66/IP67 protection, and has a conversion time of 260 ms. Its measurement error is less than 0.5 percent full scale, and it operates within a temperature range of 0 to 55 degrees Celsius.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The IE3312-B520-0000 is an I/O extension module from Beckhoff that belongs to the IE Extension Box Units series. It is designed to collect low-level thermocouple and millivolt signals on the factory floor and forward digitized data to the main controller, reducing wiring distance and cabinet space in distributed automation architectures. Mounted close to the process, this sealed block integrates sensor conditioning and fieldbus interfacing, so temperature feedback can be incorporated into motion, batching, or safety loops with minimal latency.

The module provides 4 analog inputs, each isolated from control power by 500 V to suppress ground loops between machinery and the PLC. Communication uses the DeviceNet fieldbus, so process data appear as a 4 × 16-bit image that can be read cyclically. A complete conversion cycle is finished in 260 ms, and the integrated ADC limits measurement error to < ±0.5 % FS. Cold-junction compensation is handled by the ZS2000-3712 sensor on the board, allowing direct K, J, or T thermocouple connection with 2-wire wiring. Each channel includes four selectable digital filters to balance response time against noise, and millivolt inputs can also be processed when non-thermocouple sensors must be monitored. Screw-in M12 connectors simplify replacement in washdown zones without rewiring.

For environmental resilience, the housing meets the IP65/IP66/IP67 ingress ratings, so dust and high-pressure water do not affect operation within the ambient span of 0 °C to +55 °C. Resolution of 0.1 °C per digit supports tight thermal control when the block is mounted near heaters or chillers, while digital parameters in the DeviceNet dictionary let the user match the selectable input filter to application requirements. During transport or downtime, components withstand temperatures from -25 °C to +85 °C, and the M12 interfaces maintain seal integrity.

Chan/ctrl Isolation
500 V
Channel Count
4 analog inputs
Cold Junction Comp.
ZS2000-3712
Conversion Time
260 ms
Fieldbus
DeviceNet
Input Connection
M12 screw-in
Input Filter
4 versions
Measurement Error
< ±0.5 % FS
Millivolt Input
Yes
Operating Temp.
0 °C to +55 °C
Process Image
4 x 16-bit input
Protection Class
IP65/IP66/IP67
Resolution
0.1 °C per digit
Storage Temp.
-25 °C to +85 °C
Thermocouple Wiring
2-wire

Frequently Asked Questions about IE3312-B520-0000:

Q: How many analog input channels are available on the IE3312-B520-0000?

A: The IE3312-B520-0000 features four analog input channels.

Q: Which fieldbus protocol does the IE3312-B520-0000 use?

A: This extension box unit connects via DeviceNet fieldbus for communication.

Q: What is the measurement accuracy of the IE3312-B520-0000 analog inputs?

A: The analog input measurement error is less than ±0.5% of full scale for this model.

Q: What protection class ratings does the IE3312-B520-0000 have?

A: This unit is protected to IP65, IP66, and IP67 standards for environmental resistance.

Q: What is the operating temperature range of the IE3312-B520-0000?

A: The unit operates at temperatures ranging from 0 °C to +55 °C.


Internal Product Review

  • ‘‘The IE3312-B520-0000 is a Beckhoff analog input extension box with 4 analog inputs and DeviceNet fieldbus connectivity. IP65/IP66/IP67 protection and 500 V channel-to-controller isolation support dependable deployment in demanding machine environments. Measurement error below ±0.5% FS and 0.1 °C resolution make this unit a strong choice for distributed temperature monitoring.’’