4.94 based on 220 reviews

🙶 Wake Ind. did a great job with very fast service getting us a motor driver to repair our critical robot sy... 🙷

IE2042 Beckhoff

In-Stock, Ships 1-2 Days
No Hidden Fees Rush or Credit Card
No Tariffs On US Orders

Internal Product Review

The IE2042 is a Beckhoff IE Extension Box Unit for distributed output control, featuring 8 outputs and a 24 VDC nominal voltage. Support for ohmic, inductive, and lamp loads along with 2.0 A per channel output capacity gives this unit excellent application flexibility. M12 screw-in output connections and reverse polarity protection make this model a dependable choice for machine-level installation.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The IE2042 is an output extension module produced by Beckhoff within the IE Extension Box Units series. It can be installed on a machine frame or within a drag chain as part of a distributed I/O architecture. The module expands a fieldbus segment with discrete channels that switch actuators or indicator loads in industrial automation cells.

The unit drives 8 outputs from a nominal supply of 24 VDC. Each channel can source a current of up to 2.0 A per channel, while the housing supports a cumulative load limit of 12 A to protect its internal copper traces and connectors. The outputs leave the device through a robust M12 screw-in interface that mates with standard sensor cables. Field power is supplied through two 4-pin M8 connectors, which separate the daisy-chained power feeds. Electrical isolation separates the control and fieldbus circuitry from the load side, helping protect the logic circuits from load transients. Three internally fused load circuits allow inductive, resistive, or lamp loads to be mixed without derating. Reverse-polarity protection prevents damage from accidental wiring errors. The lack of a downstream connection socket makes the box the terminating device on the power branch. The process image maps the outputs into one byte for direct addressing by a PLC.

Typical load current is 50 mA per channel, and a dedicated sensor supply rated at 0.5 A per channel allows proximity switches or optical sensors to share the field line. If a short circuit occurs, an output can briefly deliver up to 4.0 A before the protective circuitry trips, helping safeguard the upstream wiring. Signal-state feedback is provided by an integrated LED on each port, providing immediate visual confirmation of switching activity during operation.

Control/fieldbus Isolation
Yes
Downstream Connection
None
Load Circuits
3
Load Current Consumption
50 mA/Channel Typical
Load Type
Ohmic, Inductive, Lamp Load
Max Output Current
2.0 A/Channel
Max Total Current
12 A
Nominal Voltage
24 VDC
Number Of Outputs
8
Output Connection
M12 Screw-In
Power Feed
2 x M8 Connector, 4-Pin
Process Image
8 Bits Output
Reverse Polarity Protection
Yes
Sensor Supply
0.5 A/Channel Max
Short-circuit Current
4.0 A Typical
Signal State Indication
LED

Frequently Asked Questions about IE2042:

Q: Is there isolation between control and fieldbus on the IE2042?

A: Control and fieldbus circuits are electrically isolated in the IE2042 extension box for improved system reliability.

Q: What is the maximum output current supported per channel on the IE2042?

A: The IE2042 can deliver a maximum of 2.0 A output current per channel, suitable for higher-powered devices.

Q: How many outputs are available on the IE2042 extension box unit?

A: This unit provides eight individual outputs, allowing control over multiple devices simultaneously.

Q: What types of loads can be connected to the IE2042 outputs?

A: The IE2042 is designed to be used with ohmic, inductive, and lamp loads, accommodating various load types.

Q: Does the IE2042 offer reverse polarity protection?

A: Reverse polarity protection is included in the IE2042 to prevent damage from incorrect power supply connections.

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo