The ELX3314 is an EtherCAT Terminal manufactured by Beckhoff. Part of the EL EtherCAT Terminals Series, it features 4 differential inputs and supports thermocouples of various types, including K and J. The terminal offers a resolution of 0.1°C per digit. It weighs approximately 60 grams.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The Beckhoff ELX3314 EtherCAT Terminal functions as a precise industrial solution.

This device provides support for thermocouple types K, J, L, E, T, N, U, B, R, and S, together with type K acting as the pre-set standard sensor type. The broad application capability of this terminal enables it to operate in numerous industrial temperature measurement projects. The terminal operates with four differential input connections that enable simultaneous, precise temperature measurement of multiple channels. For ease of installation, the terminal requires a basic 2-wire connection that works with standard thermocouples. The measuring capabilities of Type K thermocouples extend from -270°C to +1370°C alongside measuring ±30 to ±75 mV of voltage, thus enabling wide-ranging temperature and voltage assessments. The ELX3314 product achieves precise temperature monitoring by offering a 0.1°C digit resolution accuracy level. The measurement device delivers precise results because its error level stays beneath ±0.3% when compared to full-scale measurements. The internal resistance operates at ≥10 kΩ (differential), making signal acquisition stable while reducing interference levels. Input filters found in the terminal have a 1 kHz typical limit frequency to reduce noise and achieve better measurement accuracy. The filtering capabilities depend on sensor length as well as conversion duration and sensor design for enhancing system performance across different configurations.

Through adjustment between 10 ms and 5000 ms (with 310 ms as the default), the data sampling frequency becomes adjustable on the ELX3314. The terminal operates using 24 V DC power from power contacts while consuming a typical power of 10 mA from power contacts in addition to a typical power of 70 mA from the E-bus for efficient energy management. The terminal delivers improved performance through its limit value monitoring feature, which works together with built-in digital filters and characteristic curve linearization. The terminal functions within a temperature range between -25°C to +60°C while its weight amounts to approximately 60 g, which makes it a portable and dependable component for industrial automation systems.

Connection Method
2-wire
Conversion Time
10–5000 ms adjustable (default: 310 ms)
Current Consumption (E-bus)
70 mA (typ.)
Current Consumption (power contacts)
10 mA (typ.)
Differential Input Resistance
≥ 10 kΩ
Digital Filter and Linearization
Integrated
Input Filter Cutoff Frequency
1 kHz (typ.)
Limit Value Monitoring
Integrated
Measurement Uncertainty
< ±0.3% FS
Number of Inputs
4 differential channels
Operating Temperature
-25…+60 °C
Resolution
0.1 °C
Supply Voltage
24 V DC
Supported Thermocouple Types
K, J, L, E, T, N, U, B, R, S, C (default: K)
Thermocouple Range (Type K)
-270…+1370 °C
Voltage Input Range
±30…±75 mV
Weight
≈ 60 g

Frequently Asked Questions about ELX3314:

Q: Which thermocouple types does the ELX3314 support?

A: The ELX3314 supports types K, J, L, E, T, N, U, B, R, and S, with Type K as the default, making it versatile for various industrial applications.

Q: How many temperature inputs does the ELX3314 offer?

A: It offers 4 differential input channels, allowing simultaneous and independent monitoring of multiple thermocouple signals.

Q: What helps reduce electrical noise in the ELX3314’s measurements?

A: The terminal includes input filters with a typical 1 kHz limit frequency, which helps reduce noise and improve signal clarity.

Q: Can the ELX3314 adjust data sampling speed?

A: Yes, sampling time is adjustable between 10 ms and 5000 ms, giving users flexibility in balancing performance and response time.

Q: Does the ELX3314 provide features for advanced signal handling?

A: Absolutely. It includes limit value monitoring, digital filtering, and characteristic curve linearization for precise and reliable data processing.


Internal Product Review

  • ‘‘The ELX3314 is a smart and precise solution for industrial temperature monitoring using thermocouples. Its strong sensor compatibility, noise-resistant design, and flexible setup options make it ideal for multi-point measurement applications.’’