The Beckhoff ELX3152 is part of the EL EtherCAT Terminals series and is designed for intrinsically safe devices only. It features cabinet protection rated at IP54 and can be installed in Zone 2 or non-hazardous areas. The terminal operates with a 24 VDC supply voltage and includes Ex i field interface and Ex e terminal protection.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The ELX3152 is an I/O terminal produced by Beckhoff within the EL EtherCAT Terminals series. Designed for distributed control cabinets, the unit occupies one slot on a standard EtherCAT rail and converts incoming field signals into the serial EtherCAT data stream. By integrating this terminal, system builders can route process-side sensor information from hazardous zones back to the controller without adding separate safety barriers, simplifying intrinsically safe automation architectures.

It operates from a control voltage of 24 V DC supplied through the backplane, and the internal power conversion conforms to the SELV/PELV classification so touchable circuits remain below permissible energy levels. On the field side, the interface is protected according to Ex i, meaning the energy delivered to connected loops is limited to prevent ignition in explosive atmospheres. The housing carries an IP54 cabinet protection rating; therefore, water splashes and limited dust ingress will not compromise operation when the terminal is installed in a suitable ventilated enclosure. The permitted installation area is Zone 2 or a nonhazardous location, allowing placement just outside the primary danger zone while still serving instrumentation inside it. The power feed and sensor channels share a common return through the EtherCAT power distribution, removing the need for separate field supplies.

Only intrinsically safe devices may be connected to the front terminals, and the design does not permit an external sensor supply. Each input is powered through its respective channel, ensuring that a fault on one loop cannot propagate to neighboring loops. The connector block follows the Ex e increased-safety concept, which requires reinforced clearances and captive screws. During abnormal conditions, the terminal limits the open-circuit or fault voltage to 60 V, thereby maintaining the ignition protection margin required for field circuits.

Cabinet Protection
IP54
Connected Device Type
Intrinsically Safe Devices Only
External Sensor Supply
Not Permitted
Fault Voltage Limit
60 V
Field Interface Protection
Ex i
Installation Area
Zone 2 Or Non-Hazardous Area
Power Supply Type
SELV/PELV
Sensor Supply Method
Via Respective Channel
Supply Voltage
24 VDC
Terminal Protection
Ex e

Frequently Asked Questions about ELX3152:

Q: What is the supply voltage required for the ELX3152 terminal?

A: The ELX3152 provides a supply voltage of 24 VDC for its operation.

Q: What type of devices can be connected to the ELX3152 terminal?

A: The ELX3152 is designed to connect only with intrinsically safe devices.

Q: What is the cabinet protection rating for the ELX3152 terminal?

A: This terminal offers cabinet protection rated at IP54, helping to safeguard against limited dust and water spray.

Q: Where can the ELX3152 terminal be installed safely?

A: The ELX3152 must be installed in Zone 2 or a non-hazardous area.

Q: Can an external sensor supply be used with the ELX3152 terminal?

A: External sensor supply is not permitted with the ELX3152; sensors must be supplied via their respective channel.


Internal Product Review

  • ‘‘The ELX3152 is a Beckhoff EtherCAT terminal engineered for hazardous-area signal interfacing with Ex i field interface protection and Ex e terminal protection. Operation on 24 VDC with a SELV/PELV supply supports clean integration into compliant control architectures. For Zone 2 or non-hazardous installations, this terminal is a well-executed choice for intrinsically safe device connections.’’