EL9560

    Available

Preparing your secure checkout page...

The EL9560 is an EtherCAT Terminal offering an input voltage of 24 V DC and output current of ≤ 0.1 A. Part of Beckhoff's EL EtherCAT Terminals series, it weighs approximately 65 g and supports an operating temperature range of 0–55°C. It features automatic restart after short circuit.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

Beckhoff's EL9560 is a Power supply terminal that is designed to operate seamlessly with EtherCAT systems. The terminal has the capacity to consistently distribute energy across the field and system levels that require consistent power. Beckhoff makes this power supply to meet the standard requirements for automation.

The EL9560 power supply terminal is capable of operating within a temperature range of -15 to +20 °C and requires a 24 V DC input voltage. It can supply 24 V DC and can fluctuate by up to 5 percent. The maximum output current is 0.1 A. The supply terminal uses 90 mA from the E-bus to keep its internal working steady. The protection voltage between the field and the E-bus is 1,500 V AC. This keeps the circuits separate and ensures safety during operation. The input and exit insulation can handle 500 V AC, which makes sure that the potentials are safely separated. The terminal is compliant with environmental and EMC standards, such as EN 61000-6-2 and EN 60068-2-6/27, which means that automatic control systems will work as they should. Up to 95% humidity can be present at the supply end without condensation, which ensures steady performance. The supply terminal has been approved by both CE and UL, which means it is safe and works with normal control networks.

The EL9560 power supply terminal is about 65 grams heavy, which makes it easy to place in small spaces. It can be stored at temperatures between -25 and 85 degrees Celsius, which makes it easy to handle in a variety of logistical tasks. The power supply terminal can be used in industrial automation systems that need a consistent voltage source across all terminals. It protects the circuit well and keeps the voltage output steady within controlled current limits.

Approvals
CE, UL
Current Consumption E-bus
90 mA
Emc Immunity/emission
Conforms to EN 61000-6-2/EN 61000-6-4
Input Voltage
24 V DC (-15%/+20%)
Insulation Voltage
1,500 V AC constant load field side/E-bus
Insulation Voltage Input/output
500 V AC permanent load (field side)
Operating Temperature
0…55°C
Output Current
≤ 0.1 A
Output Voltage
24 V DC (-15%/+5%)
Short-circuit Proof
Yes
Special Features
Automatic restart after short circuit, diagnostics UIN/UOUT
Storage And Operating Temperature (°c)
0 to 40 (ambient)
Storage Temperature
-25…+85°C
Vibration/shock Resistance
Conforms to EN 60068-2-6/EN 60068-2-27
Weight
Approximately 65 g

Frequently Asked Questions about EL9560:

Q: Why does the EL9560 support automatic restart after short circuits?

A: The feature minimizes downtime by automatically resuming operation post-fault resolution. It enhances system reliability without manual intervention.

Q: Does the EL9560 provide input/output voltage diagnostics?

A: Yes, it monitors input (UIN) and output (UOUT) voltages. This aids in real-time troubleshooting and performance verification.

Q: Can the EL9560 operate in high-humidity conditions?

A: Yes, it functions at 95% relative humidity without condensation. Storage tolerances extend to -25–85°C.

Q: Does the EL9560 support flexible wiring configurations?

A: It accommodates solid, stranded, and ferruled wires up to 2.5 mm². Pluggable wiring simplifies maintenance.

Q: What certifications does the EL9560 hold?

A: It carries CE and UL markings. These ensure compliance with international safety and performance standards.


Internal Product Review

  • ‘‘Beckhoff EL9560 power supply terminal delivers 24 V DC output at 0.1 A with robust 1,500 V AC insulation. It operates reliably across 0–55°C and includes diagnostics for voltage monitoring. The short-circuit proof design and automatic restart ensure minimal downtime. Its compact 65 g build suits space-constrained installations.’’