EL6070-0000 Beckhoff
Wake Industrial LLC is not an authorized distributor of this product.
The Beckhoff EL6070-0000 is part of the EL EtherCAT Terminals series and is housed in polycarbonate with dimensions of 100 mm by 12 mm by 68 mm. It installs on a 35 mm DIN rail and is rated for IP20 protection. The terminal supports a variable installation position and carries a power contact load of 10 Amps supplied via E-Bus.
Internal Product Review
The EL6070-0000 is a Beckhoff EtherCAT terminal that stands out for clean cabinet integration, with IP20 protection and variable installation position. E-Bus voltage supply simplifies wiring, while a 10 A power contact load suits steady field distribution duties. A polycarbonate housing rounds out a compact, dependable terminal for industrial EtherCAT assemblies.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The EL6070-0000 is an EtherCAT I/O terminal produced by Beckhoff and delivered within the EL EtherCAT Terminals series. Designed to occupy a single slot on a DIN rail assembly, the unit serves as a compact interface that forwards field data between an EtherCAT segment and associated control hardware inside automated machinery. It integrates with other terminals to provide time-sensitive process variables, diagnostics, and power distribution functions in industrial automation systems. This format is suited to modular control cabinets where multiple terminals are arranged side by side and exchanged through the common backplane connection.
A frontal width of 12 mm, a profile depth of 68 mm, and a module height of 100 mm allow high-density stacking without obstructing cabinet doors. The housing clips directly onto a 35 mm DIN Rail, which supports standard mounting layouts used in industrial panels. Rated IP20, the terminal is intended for enclosed installations where finger protection is sufficient. The polycarbonate housing keeps the module lightweight, and power for the internal electronics is supplied through the E-Bus backplane so no separate front-side supply wiring is needed. That arrangement leaves the front connection area available for signal routing and helps maintain an orderly terminal row.
The electrical path across the power contacts can carry up to 10 A, supporting the daisy chain of subsequent terminals without an additional feeder at every module position. For cycle-accurate logging, the Actual Time Stamp is stored as a UINT64, which provides ample range for long operating periods while preserving precise time values. For network identification, the device reports the Device Type code 0x029E1389, allowing the EtherCAT master to associate it with the correct device profile during startup. Up to 50 diagnosis messages can remain stored locally after a power cycle, which helps preserve recent fault history for later review. Variable mounting positions and the internal E-Bus voltage supply also support flexible cabinet layout.