EL3453

    In-Stock, Ships 1-2 Days

Preparing your secure checkout page...

The Beckhoff EL3453 power monitoring terminal is part of the EL EtherCAT Terminals series and supports a maximum measuring voltage of 690 V AC. It features four current and three voltage inputs, with a measurement error of 0.3% for full-scale values. Its special features include mains monitoring and phase failure detection.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The EL3453 is a Beckhoff terminal engineered to keep track of high-capacity generators. It functions as a power measurement module, enabling precise monitoring of voltage, current, frequency, and power in three-phase systems. Its ability to provide detailed measurement data makes the terminal suitable for applications in power generation plants, industrial automation setups and energy management systems. The terminal can be connected directly to high-voltage generator outputs, supporting direct measurement up to 690 V AC. It features 4 current inputs and 3 voltage inputs that enable it to simultaneously measure three-phase electrical systems while also offering an additional current input. This ensures that all critical parameters of generator output are captured in real-time for better system management.

This model also captures additional key metrics such as the power factor, total harmonic distortion (THD), and individual harmonics. By providing an extensive set of measurement data, the terminal enables detailed analysis of generator performance for efficient detection of inefficiencies or faults. This unit is designed to provide electrical isolation rated up to 4500 V, protecting both the terminal and the connected control systems from potential electrical faults.

The EL3453 terminal has a typical E-bus current consumption of 260 mA, helping to minimize the load on the E-bus. It operates optimally at -25°C to +60°C, performing reliably in both hot and cold environments. Its robust temperature tolerance ensures consistent measurement accuracy and dependable system monitoring under varying climate demands. This module is CE and UL approved, ensuring compliance with key safety and performance standards. It also comes with a 12-month Wake Industrial warranty.

Approvals
CE, UL
Current consumption (e-bus)
Typical 260 mA
Current input ranges
0.1, 1 (default), 5 A AC
Current input type
Potential-free
Distributed clocks
Optional
Measured values (electrical)
Current, voltage, P, Q, S
Measured values (others)
Energy, cos φ, frequency, THD, harmonics ≤63rd
Measurement uncertainty
±0.3% FS (U/I), ±0.6% calculated
Monitoring functions
Phase sequence, failure, asymmetry, under/overvoltage
Number of inputs
4× current, 3× voltage
Operating temperature
-25 to +60°C
Single-phase operation
Optional
Update interval
10 ms (half mains period at 50 Hz)
Update synchronization
Network-synchronous
Voltage input range
Up to 690 V AC 3~ (UL-N 400 V)
Zero-cross detection
Yes

Frequently Asked Questions about EL3453:

Q: What voltage range does the EL3453 support for generator monitoring?

A: The EL3453 supports voltage measurement up to 690 V AC in three-phase systems, allowing it to handle high-voltage generator outputs directly.

Q: How many inputs does the EL3453 have?

A: The EL3453 features 4 current inputs and 3 voltage inputs, allowing it to measure a full range of parameters in three-phase electrical systems.

Q: What is the maximum current that the EL3453 can measure?

A: The EL3453 can measure currents up to 5 A AC, with adjustable settings of 100 mA AC, 1 A AC (default), and 5 A AC. This allows it to be tailored for different generator sizes.

Q: What level of electrical isolation does the EL3453 offer?

A: The EL3453 provides electrical isolation of up to 4500 V. This high isolation protects the terminal and control systems from voltage spikes and faults, ensuring safe and reliable operation.

Q: What is the typical current consumption of the EL3453 on the E-bus?

A: The EL3453 typically consumes 260 mA from the E-bus. This efficient power consumption ensures seamless integration with other devices in the system without overloading the bus.


Internal Product Review

  • ‘‘The EL3453 offers excellent performance for monitoring high-capacity generators, with easy integration into existing systems and robust data capture. Its compact design and wide operating temperature range make it versatile for use in diverse environments. However, its 260 mA E-bus current consumption might be a concern for power-sensitive setups.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo