The EL3443-0010 is a compact EtherCAT terminal weighing approximately 75g with a 2-wire wiring connection. Manufactured by Beckhoff as part of the EL EtherCAT Terminals series, it supports a maximum measuring voltage of 480V AC 3~. It features mains monitoring, phase failure detection, and precise zero voltage crossing.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

Offered by Beckhoff, the EL3443-0010 power and energy measurement terminal has three phases. This terminals design is like that of an EtherCAT terminal. The product has three-channel analog inputs. This devices voltage is measured by connecting the L1, L2, L3, and N terminals directly. The units effective energy and power consumption for each terminal is calculated. Its current for its three phases is fed through simple current transformers. This terminal delivers extended functionality for energy management and mains analysis.

The product deploys XFC technology to transmit the time corresponding to its final zero crossing voltage. This device portrays 5 A and 48 VAC/VDC current ratings. The unit also supports a 24-bit resolution. Its user must follow the warning and safety notices in its manual to avoid property damage and/or personnel injury. This terminal has three current inputs and three voltage inputs. The product also depicts an update interval of one mains period. This device supports single-phase operation. The units terminal point N should be grounded to prevent overvoltages if there is a current transformer fault. Its point N can alternatively be connected with the neutral conductor of the mains supply.

This energy and power measurement terminals L1 to L3 LEDs illuminate in green when its voltage is within the nominal range and in red if the voltage is in the prohibited range. The product operates with six analog/digital converters to record the voltage and current values of all three phases. This device offers the DC time of the last-but-one zero crossing when the basic requirements are satisfied. The unit is not compatible with continuous loads that have a current rating higher than the technical data. Its wiring must be done to ensure that accidental contact is not possible.

Approvals/markings
CE, UL
Current Consumption E-bus
Typ. 120 mA
Measurement Error/uncertainty
0.3% relative to full scale value (U/I), 0.6% calculated value
Measuring Current
Max. 5 A (AC/DC), via measuring transformers x A/5 A
Measuring Voltage
Max. 480 V AC 3~ (UL-N: max. 277 V AC/240 V DC)
Monitoring Functions
Phase order, phase failure, phase asymmetry, undervoltage/overvoltage (adjustable)
Number Of Inputs
3 x current, 3 x voltage
Operating Temperature
-25 to +60AC
Special Features
Mains monitoring, precise detection of zero voltage crossing, optional single-phase operation
Storage Temperature
-40 to +85AC
Update Time
Net-synchronous
Weight
Approx. 75 g
Wiring
2-wire

Frequently Asked Questions about EL3443-0010:

Q: What is the cut-off frequency of the EL3443-0010 terminal?

A: The cut-off frequency of the EL3443-0010 terminal is 3000 Hz.

Q: What kind of grounded reference does the EL3443-0010 terminal have?

A: The EL3443-0010 terminal has a single-ended ground reference.

Q: What kind of sampling does the EL3443-0010 terminal support?

A: The EL3443-0010 terminal supports simultaneous sampling across all channels.

Q: What is the internal sampling rate of the EL3443-0010 terminal?

A: The internal sampling rate of the EL3443-0010 terminal is approximately 9.7 kSps per channel.

Q: What is the width alignment of the EL3443-0010 terminal?

A: The width alignment of the EL3443-0010 terminal is 12 mm.


Internal Product Review

  • ‘‘The EL3443-0010 terminal supports a standard voltage rating of 480 V for normal operating conditions. It can be easily connected to a mounting rail by applying slight pressure. The terminal's protective earth contact can ground short circuits. ’’