The Beckhoff EL3403-0026 is part of the EL EtherCAT Terminals series and features three current and three voltage input channels. It supports a maximum measuring current of 1 Amp AC and 500 V AC across three phases, with a resolution of 1 microampere, 0.1 millivolt, and 10 milliwatt. The terminal measures using a true RMS procedure and has a protection rating of IP20.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The EL3403-0026 is a three-phase power measurement terminal produced by Beckhoff within the EL EtherCAT Terminals series. By inserting it on the EtherCAT I/O strand, the system can record line voltages and currents for each phase and forward the data to the controller in real time, allowing consumption tracking, condition monitoring, and closed-loop energy optimization in industrial automation networks. Its integrated metrology replaces external transducers and reduces panel space while still delivering synchronized bus data.

The terminal samples each phase in sync with the mains, and this mains-synchronous conversion time helps ensure every half-wave is captured without aliasing. Equally important, the data are transmitted on the bus with a net-synchronous update time, so the measurements line up with the distributed clocks of other EtherCAT devices. The analog measurement section includes 3 x current, 3 x voltage channels that feed a true RMS engine and can resolve signals down to 1 µA, 0.1 mV, 10 mW, enabling precise low-level profiling. Electrical limits permit direct connection up to 500 V AC 3~ and up to 1 A AC per channel, covering typical motor feeders without external transformers.

On the supply side, the terminal draws 120 mA typ. from the E-bus and can pass up to 10 A through its power contacts to downstream modules, so no additional feed segment is necessary for small load groups. The measurement chain maintains a combined accuracy of 0.5 % for voltage and current and 1 % for derived quantities, aided by a single-ended ground reference and simple 2-wire field wiring. A 62-byte process image for input and a 3-byte image for output transfer the raw values plus status bits to the PLC. The housing measures 12 x 100 x 68 mm, carries an IP20 rating, and slots into the standard DIN-rail carrier without tools.

Conversion time
Mains-Synchronous
Dimensions (w X H X D)
12 x 100 x 68 mm
E-bus Current
120 mA Typ.
Ground Reference
Single-Ended
Input Channels
3 x current, 3 x voltage
Max Measuring Current
1 A AC
Max Measuring Voltage
500 V AC 3~
Measurement Error
0.5% (U/I), 1% Calculated
Measuring procedure
True RMS
Power Contact Load
10 A
Process Image
62 B PM In / 3 B PM Out
Protection Rating
IP20
Resolution
1 µA, 0.1 mV, 10 mW
Update time
Net-Synchronous
Wiring
2-wire

Frequently Asked Questions about EL3403-0026:

Q: What is the maximum measuring voltage supported by the EL3403-0026?

A: The EL3403-0026 terminal can measure up to 500 V AC in a three-phase system.

Q: How many input channels does the EL3403-0026 terminal have?

A: This model provides three current and three voltage input channels for measurement.

Q: What are the resolution values for current, voltage, and power on the EL3403-0026?

A: The EL3403-0026 achieves measurement resolutions of 1 µA, 0.1 mV, and 10 mW.

Q: What is the stated measurement error for the EL3403-0026 terminal?

A: Measurement error is specified at 0.5% for voltage and current, and 1% for calculated values.

Q: What is the maximum measuring current per channel for the EL3403-0026?

A: It supports a maximum measuring current of 1 A AC for each input channel.


Internal Product Review

  • ‘‘The EL3403-0026 is a Beckhoff EtherCAT power measurement terminal with 3 current and 3 voltage input channels for comprehensive AC monitoring. True RMS measurement and 0.5% voltage/current measurement error give the terminal very dependable data quality in distributed control applications. Support for up to 500 V AC 3~ and mains-synchronous conversion makes this unit an excellent choice for precise three-phase energy analysis.’’