The EL3356 is a compact EtherCAT terminal weighing approximately 60 grams with 16-bit resolution and a 10 kHz low-pass input filter frequency. Designed by Beckhoff as part of their EL EtherCAT Terminals, it supports a nominal sensitivity of 0.5–4 mV/V and features a power supply via the E-bus. It operates within a temperature range of -25 to +55°C.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The Beckhoff EL3356 represents an EL EtherCAT Terminal that provides high precision for industrial requirements.

The full bridge technology within its dual-input functionality allows it to precisely measure strain gauges or load cells. The E-bus provides a power supply to enable an efficient integration process when working within EtherCAT systems. This terminal can measure bridge voltages from ±27 mV to ±13.8 V simultaneously, catering to a wide range of applications through its supply voltage measuring range. The terminal exhibits more than 200 kΩ internal resistance for U_REF alongside 1 MΩ or greater resistance for U_D to reduce signal disturbances during measurements. The EL3356 functions best when operated in nominal sensitivity ranges from 0.5 to 4 mV/V with parameter resolution set at 0.01 µV/V to achieve precise measurements. The terminal contains a low-pass input filter that sets the limit frequency to 10 kHz to reduce high-frequency noise that may impact accuracy. Despite different needs, the terminal provides a conversion rate adjustment of 100 to 4 samples per second, which corresponds to a conversion time range between 10 to 250 ms. A 32-bit presentation supports a 16-bit resolution that enables the terminal to record measurement details with high precision.

The measurement error level remains low because the calculated load value shows maximum deviations under ±0.01% in this measurement process. The E-bus uses 210 mA of current reliably as a power-saving measure for extended operation periods. It operates between -25°C to +55°C, which provides broad industrial environment compatibility. This device weighs approximately 60 grams, making it convenient for incorporation into control systems. The terminal maintains an input impedance of more than 100 MΩ to avoid impacting measured signals and delivers precision measurements through its differential output design, which reduces environmental noise.

Conversion Rate
100–4 samples/s (10–250 ms conversion time)
Current Consumption E-bus
typ. 210 mA
Input Filter Limit Frequency
10 kHz low pass (-3 dB)
Input Impedance
> 100 MΩ
Internal Resistance
> 200 kΩ (U_REF), > 1 MΩ (U_D)
Measurement Error/uncertainty
< ±0.01% for the calculated load value
Measuring Range U D (bridge Voltage)
max. ±27 mV
Measuring Range U Ref (supply Voltage)
max. ±13.8 V
Number Of Inputs
2, for 1 resistor bridge in full bridge technology
Operating Temperature Range
-25…+55°C
Power Supply
via the E-bus
Resolution
16 bit, 32 bit presentation
Signal Output Format
Differential Output
Supported Nominal Sensitivity
0.5…4 mV/V (recommended), parameter resolution: 0.01 µV/V
Weight
Approx. 60 g

Frequently Asked Questions about EL3356:

Q: What types of sensors are compatible with the EL3356 terminal?

A: The EL3356 is compatible with full-bridge sensors like strain gauges and load cells, offering accurate analog signal measurement through its dual input channels.

Q: What is the bridge voltage input range for the EL3356?

A: The EL3356 can measure bridge voltages ranging from ±27 mV to ±13.8 V, supporting a broad range of measurement applications.

Q: How accurate are the measurements taken by the EL3356?

A: The terminal maintains high accuracy with a resolution of 0.01 µV/V and measurement error deviations limited to ±0.01%.

Q: Does the EL3356 filter out high-frequency noise?

A: Yes, it includes a low-pass input filter that limits the frequency to 10 kHz, effectively minimizing high-frequency noise for cleaner signal processing.

Q: What is the sampling rate range of the EL3356?

A: The EL3356 supports a conversion rate from 100 to 4 samples per second, translating to conversion times between 10 ms and 250 ms.