The EL2912 is a Beckhoff safety output terminal configured with 2 safe outputs and a 24 V DC nominal load voltage. Support for ohmic, inductive, and lamp loads with 2 A output current makes the unit especially effective for safety-related switching duties. SIL 3 and PL e ratings make the EL2912 an excellent fit for high-integrity machine safety systems.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The EL2912 is a safety output terminal in the EL EtherCAT Terminals series produced by Beckhoff. Within an EtherCAT I/O rack, it provides two switchable channels that disconnect external loads whenever a fault is detected. This function allows the terminal to form part of a machine’s emergency-stop or protective-interlock circuitry. The terminal is intended for industrial automation systems that use distributed I/O over the EtherCAT fieldbus and require certified functional safety at the I/O layer. Its compact terminal format also allows the safety channels to be installed alongside standard EtherCAT terminals in a control cabinet.

The outputs operate on a nominal supply of 24 V DC, and each channel can source or sink up to 2 A. This capacity allows direct actuation of compatible contactors, solenoids, and indicator lamps without auxiliary relays. Connection uses a single-conductor scheme identified as 1-wire, which simplifies field wiring by reducing the number of conductors required at each connection point. The internal switching elements support resistive, inductive, and lamp loads, allowing the terminal to control heaters, coils, and filament lamps within the stated current limit. The module satisfies performance level PL e under ISO 13849-1 when it is integrated with the required diagnostics and fault exclusions. The safety controller can monitor the channels through the EtherCAT system and command them according to the configured protective logic.

The housing meets protection class IP20, so the terminal must be installed inside a suitable control cabinet. This protection level guards against contact with hazardous internal parts and ingress by larger solid objects, but it does not protect the unit against water. The module uses two fail-safe switching transistors to provide individual safe outputs that can shut off simultaneously or independently according to the configured safety logic. The circuitry is certified to SIL 3 according to IEC 61508, supporting applications that require a low probability of dangerous failure during continuous operation. Proper cabinet placement, wiring, and safety logic are necessary to preserve the intended protective behavior of the output channels.

Connection Technology
1-wire
Load Type
Ohmic, Inductive, Lamp Load
Nominal Load Voltage
24 V DC
Output Current
2 A
Performance Level
PL e
Protection Class
IP20
Safe Outputs
2
Safety Level
SIL 3

Frequently Asked Questions about EL2912:

Q: How many safe outputs does the EL2912 terminal include?

A: The Beckhoff EL2912 EtherCAT terminal provides two safe outputs for enhanced safety-related control processes.

Q: What is the nominal load voltage for the EL2912 from Beckhoff?

A: This terminal operates with a nominal load voltage of 24 V DC, making it suitable for typical industrial control circuits.

Q: What is the maximum output current per channel on the EL2912?

A: Each output of the EL2912 can supply up to 2 A current to connected devices.

Q: What safety certifications does the Beckhoff EL2912 terminal have?

A: The EL2912 achieves safety level SIL 3 and performance level PL e, meeting stringent industrial safety requirements.

Q: Which types of loads can the EL2912 safe output terminal control?

A: The EL2912 supports ohmic, inductive, and lamp load types, allowing flexible application options.