EL2535-0005
Wake Industrial LLC is not an authorized distributor of this product.
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The EL2535-0005 EtherCAT terminal features two outputs, a nominal voltage of 24 V DC (-15%/+20%), reverse voltage protection, and a default PWM clock frequency of 30 kHz. Part of Beckhoff's EL EtherCAT Terminals series, it operates efficiently at temperatures up to 55AC and is CE, CCC, ATEX, IECEx, and cFMus approved.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
Designed by Beckhoff, this EL2535-0005 EtherCAT terminal is characterized by a PWM output. This product controls proportional and solenoid valves with single and double coils. It uses Pulse Width Modulation (PWM) of the supply voltage to regulate the output current and this terminal offers electrical isolation from the E-bus. Its outputs are equipped with short circuit and overcurrent protection. The terminal's current values are specified through a 16-bit value.
This product's signal stages are highlighted by LEDs. The device's PWM stages portray a push-pull output stage. This unit is an ideal option for inductive loads greater than 1 mH. It has a maximum 5 A output current at 24 VDC nominal voltage for both channels. The terminal offers no assurance of safe operation with hardware or software modification. This product is identified by a unique identification code. The device-associated ESI-EEPROM stores the ESI/XML configuration file for the EtherCAT master. This unit's light emitting diodes simplify the diagnosis process. It supports inductive loads.
The EtherCAT terminal's feed-in points of cables tend to depict a temperature of higher than 70 C when its operation is done. This product's ambient operating temperature range must never be exceeded when it functions in a potentially explosive area. The device's cable length must not exceed 100 m when the connection is made between two EtherCAT terminals. This unit features a 5 V E-bus system voltage when it is connected to a bus coupler. Its watchdog safety feature switches off the outputs after a specified time when the process data traffic is interrupted.
Frequently Asked Questions about EL2535-0005:
Q: What kind of outputs does the EL2535-0005 terminal have?
A: The EL2535-0005 terminal has push-pull PWM outputs.
Q: What is the nominal voltage of the EL2535-0005 terminal?
A: The nominal voltage of the EL2535-0005 terminal is 24 VDC with -15%/20% tolerance.
Q: What is the maximum output current of the EL2535-0005 terminal?
A: The maximum output current of the EL2535-0005 terminal is 5 A up to 40 AC operating temperature.
Q: How many inputs does the EL2535-0005 terminal have?
A: The EL2535-0005 terminal has two digital 24 V inputs.
Q: What is the resolution of the EL2535-0005 terminal?
A: The EL2535-0005 terminal has a 10-bit resolution.