4.94 based on 219 reviews

🙶 We have never had a problem in the almost 20 years we have dealt with Wake. We would recommend them to any... 🙷

EL1859 Beckhoff

In-Stock, Ships 1-2 Days
No Hidden Fees Rush or Credit Card
No Tariffs On US Orders

Internal Product Review

The EL1859 is a Beckhoff EtherCAT terminal with 8 inputs and 8 outputs for efficient distributed I/O handling. A 24 VDC nominal input and short-circuit protection support dependable integration in standard automation panels. Switching times of 60 µs TON and 300 µs TOFF make the EL1859 especially well suited for responsive signal processing.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The EL1859 is a digital combination terminal produced by Beckhoff for the EL EtherCAT Terminals series. Designed for distributed control systems, the device integrates eight input channels and eight output channels into a single slice, allowing field wiring to be concentrated on the bus rail. By providing both signal directions in one housing, the terminal reduces node count, conserves panel space, and delivers deterministic updates through EtherCAT. Its compact format supports connections between on-machine sensors, actuators, and the PLC.

Signal connections use the 1-Wire concept, which lets each channel share a common supply reference while minimizing conductor count. All inputs are referenced to a nominal 24 VDC sensor supply, and an internal 3 ms filter suppresses contact bounce before data are forwarded to the controller. The local E-bus typically draws only 130 mA, so the terminal imposes a modest load on the backplane power feed. Each output can source up to 0.5 A, enabling direct actuation of small relays or indicator lamps without an external driver. The housing locks onto a 35 mm DIN mounting rail, aligning the spring terminals with adjacent Beckhoff I/O terminals. The process image is organized as eight input bits and eight output bits for predictable mapping within TwinCAT.

The input sensing circuits draw only 3 mA per channel, while the power contacts require 15 mA plus the switched load, keeping total cabinet power consumption low. The terminal carries an IP20 protection rating, so it is intended for installation within an enclosure but does not require separate terminal covers. Reverse-voltage protection is provided on the supply pins, and built-in short-circuit detection disconnects an output if an overload occurs. Typical switching times of TON 60 µs and TOFF 300 µs support rapid control sequences without introducing excessive timing delays. These response times make the terminal suitable for operating devices such as compact solenoids and indicator circuits. The integrated protective functions also help prevent electrical faults on individual outputs from disrupting the remaining connected channels.

Connection Technology
1-Wire
E-bus Current
130 mA Typ.
Input Current
3 mA Typ.
Input Filter
3 ms
Input Nominal Voltage
24 VDC
Mounting Rail
35 mm
Number Of Inputs
8
Number Of Outputs
8
Output Current
0.5 A
Power Contact Current
15 mA + Load Typ.
Process Image
8 Input Bits, 8 Output Bits
Protection Class
IP20
Reverse Voltage Protection
Yes
Short-circuit Protection
Yes
Switching Times
TON 60 µs, TOFF 300 µs Typ.

Frequently Asked Questions about EL1859:

Q: How many input and output channels are available on the EL1859 terminal?

A: The EL1859 offers 8 digital inputs and 8 digital outputs for versatile signal processing tasks.

Q: What is the nominal input voltage for the EL1859 EtherCAT terminal?

A: The nominal input voltage required for the EL1859 terminal is 24 VDC.

Q: What is the maximum current per output channel on the EL1859?

A: Each output channel on the EL1859 can supply up to 0.5 A of current.

Q: Does the EL1859 provide built-in protection against reverse voltage and short circuits?

A: The EL1859 is equipped with both reverse voltage and short-circuit protection.

Q: What is the typical input filter time for the EL1859 terminal?

A: This terminal features a typical input filter time of 3 milliseconds, helping reduce signal noise.