CX2900-0103 Beckhoff
Wake Industrial LLC is not an authorized distributor of this product.
The Beckhoff CX2900-0103 is part of the CX Embedded PC Systems series and has dimensions of 66 mm width, 67 mm height, and 16 mm depth. This module features a 60 mm fan with a maximum speed of 5900 rpm and a service interval of 5 years. The system has a high temperature threshold of 85°C and a low temperature fan speed of 2400 rpm.
Internal Product Review
The CX2900-0103 is a Beckhoff cooling fan module for CX Embedded PC systems with a compact form factor and a 5-year service interval. Temperature-based operation between the 40 °C low threshold and 85 °C high threshold supports consistent thermal control in cabinet installations. A maximum fan speed of 5900 rpm and a fault speed threshold of 1000 rpm make this unit a dependable choice for monitored cooling performance.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The CX2900-0103 cooling module is produced by Beckhoff for integration with CX Embedded PC Systems controllers. It is an active fan unit that attaches to a CX processor housing to remove heat generated during continuous PLC or motion-control duty. By regulating internal temperature, the module protects the electronics and helps maintain stable operation in industrial automation racks. Its role is especially important in compact control assemblies where processor heat can build up during long operating cycles.
The unit has a depth of 16 mm, a width of 66 mm, and a height of 67 mm, so it can be added without increasing rail spacing beyond the controller profile. Airflow is delivered through a centrifugal impeller with a 60 mm diameter. These proportions match the existing CX heat-sink recess, so the cooler can slide into place without disturbing adjacent modules. When the housing temperature drops below the low-temperature threshold, the controller commands a baseline speed of 2400 rpm to reduce unnecessary wear on the fan assembly. Continuous monitoring inside the CX system adjusts cooling output as thermal demand changes during normal operation.
During demanding cycles, the fan can reach a maximum speed of 5900 rpm, while a fault is triggered if rotation falls below 1000 rpm. This allows the control system to detect reduced airflow before a complete stall occurs. Temperature supervision sets an upper alarm at 85 °C, prompting maximum airflow until the processor block cools. The module has a 5 years service interval for the bearings and filter mat, allowing routine replacement to be planned during scheduled downtime. Diagnostic monitoring can also issue warnings through the control system while the fan is still operating, which supports early attention to cooling performance.