BK4500

    In-Stock, Ships 1-2 Days

Preparing your secure checkout page...

The BK4500 by Beckhoff is part of the BK EtherCAT Bus Couplers series and operates with a power supply of 24V (-15% to +20%). It supports 256 digital and 32 analog peripheral signals, with a maximum K-bus output current of 1750 mA. The unit features 500 Vrms isolation and IP20 protection.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The BK4500 is a high-speed Bus Coupler used for back peripheral signals with centralized control. It offers the maximum current supply of 900 mA and solid K-bus current of 1750 mA, thus working steadily even for heavy configurations. The BK4500 is made for modular mounting and can potentially accommodate 64 terminals in the sense of holding potential feed, as well as end terminals, with excellent expandability.

The unit is capable of handling up to 256 digital inputs and outputs, and up to 32 analog inputs and outputs with an adequate number of point connections for a variety of field devices. Operating at a rate of data transfer of 500 KBaud, the BK4500 offers rapid communication between devices and therefore finds application in applications where time plays a critical factor. The module has introduced dielectric strength of 500 Vrms between periphery power supply and K-bus, and between power contact and InterBus incoming signal voltage. Such a level of potential isolation introduces operational safety through effective isolation of different voltage domains in the system. Electrical interference is minimized by such protection to allow stable operation, and it prevents signal degradation. The BK4500 is optimally used in installations where coordination of more than one digital and analog device is to be accomplished through InterBus. Its compactness and high signal handling capacity make it a fit candidate to be used in industrial automation, building management, and machine control.

Expansion through addition of terminals is provided for accommodating future requirement without changing the present configuration. Its robust build satisfies industrial demands for signal integrity, and therefore it is a reliable and extremely extensible interface. The BK4500 enables accurate communication, power management, and signal integrity in a compact, highly integrated form factor with flexible expansion.

Analog Peripheral I/O
32 inputs and outputs
Bus Baud Rate
500 kBaud
Bus Terminals
64
Digital Peripheral I/O
256 inputs and outputs
Input Current
105 mA typ., 900 mA max.
Isolation Voltage (K-bus/power supply)
500 Vrms
Isolation Voltage (power contact/InterBus)
500 Vrms
K-Bus Output Current
1750 mA max.
Operating Temperature
0°C to +55°C
Power Contact Current Load
10 A
Power Contact Voltage
24 V DC/AC
Protection Type
IP20
Supply Voltage
24 V (-15%/+20%)

Frequently Asked Questions about BK4500:

Q: What is the input current for the BK4500?

A: The input current is 105 mA typically, 900 mA maximum.

Q: What is the K-bus output current for the BK4500?

A: The BK4500 provides a maximum K-bus output current of 1750 mA.

Q: How many bus terminals can the BK4500 support?

A: It supports up to 64 terminals including potential and end terminals.

Q: What is the power contact voltage on the BK4500?

A: The power contact voltage is 24 V DC/AC.

Q: What is the protection class of the BK4500?

A: It has an IP20 protection rating.


Internal Product Review

  • ‘‘The BK4500 bus coupler operates reliably within large-scale modular systems. Its performance remains consistent, even when supporting numerous terminals. Setup is straightforward, and the structure supports both analog and digital signals with ease. An excellent choice for scalable control system configurations.’’