★★★★★
4.94 based on 222 reviews

🙶 a+ fast delivery 🙷

BK3100 Beckhoff

In-Stock, Ships 1-2 Days
No Hidden Fees Rush or Credit Card
No Tariffs On US Orders

Internal Product Review

The BK3100 is a Beckhoff bus coupler that delivers clean integration and dependable communication for demanding automation tasks. Support for 512 digital inputs/outputs and 128 analog inputs/outputs gives the unit excellent I/O density for complex control architectures. Capacity for 64 Bus Terminals and a 12 Mbaud max baud rate makes the BK3100 a highly capable choice for fast, efficient panel-level control.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The BK3100 PROFIBUS DP Bus Coupler is produced by Beckhoff for the BK Bus Couplers series. It links PROFIBUS fieldbus traffic to the manufacturer’s modular K-bus I/O terminals, allowing decentralized modules to be addressed through a single device address in an industrial control system. By translating process data between the PROFIBUS master and as many as 64 terminal positions, the unit provides a compact interface for distributed sensors, actuators, and analog channels in factory automation. The coupler mounts at the beginning of a terminal assembly and transfers incoming control data to the connected I/O modules. Return data from those terminals is then transmitted to the higher-level controller through the same fieldbus connection.

On the signal side, the coupler can handle up to 512 digital inputs and outputs and an additional 128 analog inputs and outputs, allowing large mixed configurations without a second head station. A shielded 9-pin D-sub connector forms the bus connection and supports a line speed of 12 Mbaud, matching the maximum data rate available for the supported PROFIBUS network. Internally, the K-bus delivers up to 1750 mA, providing logic power to the attached terminals. The electronics and downstream power contacts operate from a regulated 24 V DC source. When the device is used in DP-only mode, it can exchange 128 bytes of cyclic process data. Selecting combined DP/FMS communication reduces the available process image to 64 bytes.

The housing is intended for control-cabinet installation and measures 50 mm wide, 68 mm deep, and 100 mm high, allowing multiple couplers to fit on a standard DIN rail without obstructing adjacent equipment. Power contacts routed through the coupler can carry 10 A to the field terminals, while a dielectric strength of 500 V provides insulation between the supply and logic sections. Up to 64 bus terminals can be installed on the right side of the coupler, with each terminal connected through the integrated K-bus. The enclosure has an IP20 protection rating, making it suitable for installation inside an indoor industrial control cabinet. Its housing protects against contact with hazardous internal parts and the entry of solid objects larger than the applicable protection threshold.

Analog Peripheral Signals
128 inputs/outputs
Bus Connection
1 x D-sub plug, 9-pin, shielded
Depth
68 mm
Dielectric Strength
500 V
Digital Peripheral Signals
512 inputs/outputs
Height
100 mm
K-bus Current
1750 mA
Max Baud Rate
12 Mbaud
Max Process Data (dp Only)
128 bytes
Max Process Data (dp/fms)
64 bytes
Number of Bus Terminals
64
Power Contact Load
10 A
Power Contact Voltage
24 VDC
Power Supply
24 VDC
Protection Class
IP20
Width
50 mm

Frequently Asked Questions about BK3100:

Q: How many analog peripheral signals can the Beckhoff BK3100 handle?

A: The BK3100 supports up to 128 analog input or output signals for peripherals.

Q: What type of bus connection is provided on the BK3100?

A: This bus coupler features a 1 x D-sub 9-pin, shielded bus connection for secure data transmission.

Q: How many digital peripheral signals can the Beckhoff BK3100 support?

A: The maximum digital peripheral capacity of the BK3100 is 512 inputs or outputs.

Q: What is the maximum number of bus terminals that can be connected to the BK3100?

A: The BK3100 accommodates a maximum of 64 bus terminals for modular expansions.

Q: What are the power supply requirements and maximum power contact load for the BK3100?

A: The device operates with a 24 VDC power supply and supports a power contact load of up to 10 A.

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo