4.94 based on 222 reviews

🙶 We have never had a problem in the almost 20 years we have dealt with Wake. We would recommend them to any... 🙷

BK3000 Beckhoff

In-Stock, Ships 1-2 Days
No Hidden Fees Rush or Credit Card
No Tariffs On US Orders

Internal Product Review

The BK3000 is a Beckhoff bus coupler that supports 64 Bus Terminals and up to 244 I/O bytes for efficient field-level integration. Technical capability is impressive, with capacity for 512 digital signals and 128 analog signals that fits demanding control layouts. IP20 protection and a 24 VDC power supply make this coupler a dependable choice for cabinet-based automation.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The BK3000 is a Beckhoff bus coupler from the BK PROFIBUS Bus Couplers series. It functions as the gateway between a PROFIBUS network and the modular K-bus I/O system, allowing attached terminal blocks to be addressed with deterministic cycle times. By translating network messages into local backplane data, the unit lets a PLC poll sensors, actuators, and mixed-signal modules without additional interface cards. This arrangement reduces cabinet space and wiring requirements in distributed control architectures.

On the network side, the coupler supports transfer rates up to 1.5 Mbaud, and communication is routed through a single 9-pin D-sub connector to simplify trunk wiring. The module can accommodate up to 128 analog inputs and outputs and as many as 512 digital inputs and outputs. These limits determine the permitted scale of a terminal stack before another node is required. The controller transfers 244 bytes per cycle across all mapped variables. Its internal electronics draw no more than 500 mA, while the integrated K-bus can supply 1,750 mA to downstream terminals. The coupler supports 64 K-bus slots, and an inrush limiter restricts starting current to 2.5 times the steady-state draw. Functional isolation between field power and logic provides a dielectric strength of 500 V.

The housing measures 50 × 100 × 68 mm, making the unit narrow enough for installation on a standard 35 mm rail. The internal fuse and power contacts are each rated for 10 A, allowing branch loads to be supplied through the coupler without additional distribution blocks. Field devices receive power at 24 VDC, which is also the voltage required by the coupler’s logic circuits. The enclosure has an IP20 protection rating, making it finger-safe while leaving it unprotected against water. It must therefore be installed inside a suitable cabinet that shields it from moisture and conductive dust.

Analog Signals
128 inputs/outputs
Baud Rate
1.5 Mbaud max.
Bus Connection
1 x D-sub, 9-pin
Bus Terminals
64
Dielectric Strength
500 V
Digital Signals
512 inputs/outputs
Dimensions (w X H X D)
50 x 100 x 68 mm
Fuse Rating
10 A max.
Input Current
500 mA max.
K-bus Current
1750 mA max.
Max I/o Bytes
244 bytes
Power Contact Current
10 A max.
Power Contact Voltage
24 VDC max.
Power Supply
24 VDC
Protection Class
IP20
Starting Current
2.5 x continuous current

Frequently Asked Questions about BK3000:

Q: How many digital inputs and outputs are supported by the BK3000 EtherCAT Bus Coupler?

A: The BK3000 can handle up to 512 digital input/output signals, supporting large applications that require extensive digital connections.

Q: What is the maximum number of analog inputs and outputs on the BK3000?

A: This model supports up to 128 analog inputs or outputs, allowing for versatile analog signal integration within control systems.

Q: What is the dielectric strength of the BK3000 coupler?

A: The BK3000 has a dielectric strength of 500 V, providing electrical isolation for enhanced safety.

Q: What power supply voltage is required for the BK3000 bus coupler?

A: The BK3000 operates with a maximum power supply voltage of 24 VDC, aligning with many standard industrial control systems.

Q: How many I/O bytes can the BK3000 EtherCAT Bus Coupler manage at maximum?

A: With a maximum I/O capacity of 244 bytes, this unit efficiently handles extensive data exchange between I/O terminals and the controller.