BK2020

    Available

Preparing your secure checkout page...

The BK2020 is a robust bus coupler supporting up to 64 terminals or 255 with a K-bus extension. Manufactured by Beckhoff as part of the BK EtherCAT Bus Couplers series, it has a power supply of 24 V DC and supports a data transfer rate of 2.5 Mbaud. It handles 1,020 digital peripheral signals with an operating range of 0 to 55°C.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

Beckhoff produces BK2020 Lightbus Bus Coupler designed for industrial automation. It supports up to 64 bus terminals, expandable to 255 terminals with the K-bus extension. The coupler enables quick signal management through its 1,020 digital peripheral inputs and outputs. It also provides 128 analog peripheral inputs and outputs for accurate analog data processing.

The BK2020 bus coupler operates through fiber-optic conductors to provide steady data transfer between fieldbus systems. The data transfer relies on two types of fiber optic cables: the APF plastic with a 1,000 µm core diameter and the HCS with a 200 µm core diameter. The coupler operates at a 2.5 Mbaud data transfer speed with input-output capabilities up to 512 bytes each. It contains two standardized fiber-optic connectors that manage bus interface connections. The maximum distance between stations is 45 meters when using APF fiber and extends to 300 meters with HCS fiber. The recommended fuse rating for the BK2020 bus coupler is less than or equal to 10 A. The bus coupler functions within the temperature range of 0 to 55°C for industrial applications. The power supply requirements demand a 24 V DC voltage which can operate with a range of -15% to +20%. The K-bus supply draws 1,750 mA of current. However, the input current equals 70 mA, along with a quarter of the K-bus current total. The bus coupler maintains input current levels that stay below 500 mA.

The BK2020 bus coupler offers dependable data transfer along with modular system connection capabilities for processing both digital and analog signals. Configuration is possible through this bus coupler software tool or directly via the controller. The coupler ensures stable data exchange across fieldbus systems using fiber-optic conductors. At the beginning of operation, the current level reaches approximately 2.5 times the operating current level.

Analog peripheral I/O
128 I/O
Bus interface
2× connectors Z1000 (APF), Z1010 (HCS)
Configuration method
Via KS2000 or controller
Data transfer rate
2.5 Mbaud
Digital peripheral I/O
1020 I/O
Fiber-optic medium
APF (Ø1000 µm) or HCS (Ø200 µm)
Fieldbus buffer
512 bytes IN, 512 bytes OUT
K-bus current supply
1750 mA
Module input current
70 mA + (K-bus current)/4; max 500 mA
Number of bus terminals
64 (up to 255 with K-bus)
Operating temperature
0–55 °C
Recommended fuse
≤ 10 A
Starting current
~2.5× continuous current
Station distance
45 m (APF), 300 m (HCS)
Supply voltage
24 V DC (-15%/+20%)

Frequently Asked Questions about BK2020:

Q: How does the 24 V DC supply improve BK2020 stability?

A: The 24 V DC supply of BK2020 offers a wide tolerance range of -15% to +20%, allowing it to handle voltage fluctuations common in industrial environments.

Q: How does temperature range support enhance BK2020 durability?

A: The BK2020 operates efficiently between 0 to 55°C, ensuring stable performance in varying industrial environments without risk of thermal malfunction.

Q: How does BK2020 maintain input current below 500 mA?

A: The BK2020 bus coupler regulates power by combining 70 mA base consumption with a fraction of the K-bus current, preventing overloads during operation.

Q: What is the role of the 1,750 mA K-bus current in BK2020?

A: The 1,750 mA K-bus current powers the connected terminals and ensures that multiple I/O modules operate without external power interruptions, enhancing system resilience.

Q: Why are two fiber types (APF and HCS) supported in the BK2020?

A: The BK2020 allows flexibility by supporting APF for short ranges up to 45 meters and HCS for longer ranges up to 300 meters, improving installation versatility.


Internal Product Review

  • ‘‘The Beckhoff BK2020 bus coupler excels in industrial automation. It features 2.5 Mbaud speed, modular K-bus expansion up to 255 terminals, and 1,020 digital I/O capacity. It has Dual fiber-optic connectivity ensures stable transmission. Its compact design and 24 V DC operation enhance system reliability. BK2020 delivers industry-grade performance.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo