The X20SLX811 is a compact I/O module measuring 12.5mm x 100mm x 72mm with IP20 protection class. Manufactured by B & R Automation, it belongs to the X20 Fieldbus Input Output Modules series and is mounted on a DIN rail. Featuring hot swap capability, it operates within a temperature range of 0 to 60°C.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
Supplied by B & R Automation, the X20SLX811 digital input module incorporates SafeLOGIC functionality. This module executes applications designed using the manufacturer's SafeDESIGNER safety software. The product portrays suitability for SIL 3 and PL e safety applications. This device incorporates a SafeLOGIC controller to coordinate the safety-related communication of the modules used in the application. The unit's digital input channels are used for various tasks that involve reading digital signals. Its inputs have filters that are configurable for a switch-off or a switch-on action. This module uses pulse signals to diagnose the sensor line.
The product has a protective coating on its components to safeguard them against condensation. This device comprises a sink-type input circuit. The unit's input filter has a software setting that can be configured between 0 ms and 500 ms. It depicts a single-width design. This module houses four pulse outputs. The product uses the Automation Studio 4.0 or later for its operation. This device features channel-to-bus electrical isolation. The unit supports 64 BOOL machine operations. It has a 500 V isolation voltage between the channel and the bus.
This digital input module is integrated with a sink input circuit. The product housing should have no condensation during transport or storage. This device should never be operated outside its specified technical data. The unit comprises five LED status indicators for fault diagnostics. Its wiring must be checked when the same pulse signal is used for or applied to two adjacent inputs on the terminal.
Frequently Asked Questions about X20SLX811:
Q: What is the color of the X20SLX811 module?
A: The X20SLX811 module is yellow in color.
Q: What does the SE LED of the X20SLX811 module indicate?
A: The SE LED of the X20SLX811 module indicates the status of its safety processors.
Q: How many openSAFETY nodes does the X20SLX811 module have?
A: The X20SLX811 module has 11 openSAFETY nodes.
Q: What is the maximum I/O cycle time of the X20SLX811 module?
A: The maximum I/O cycle time of the X20SLX811 module is 1 ms.
Q: What is the protection class of the X20SLX811 module?
A: The protection class of the X20SLX811 module is IP 20.