The X20SL8011 module is manufactured by B & R Automation as part of the X20 Fieldbus Input Output Modules series. It features a POWERLINK interface, transfer rate of 100 Mbit/s, and supports a maximum fieldbus cycle time of 20 ms. The module supports up to 100 safety nodes with SIL 3 and Cat. 4 safety category, and has a power consumption of 5.1 W with IP20 protection.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The X20SL8011 is a safety controller module produced by B&R Automation for the X20 Fieldbus Input Output Modules series. Installed on X20 backplanes, it provides logic processing for distributed safety I/O and communicates with standard control CPUs over the POWERLINK network. Within an automation cell, it supervises safety-related inputs and outputs so machinery can move to a predefined safe state when a fault is detected, making it a central part of integrated machine safety.

Thermal management is simplified because the unit uses fanless cooling, and the housing carries an IP20 degree of protection for cabinet-mounted environments. Its enclosure measures 87.5 +0.2 mm in width, 75 mm in depth, and 99 mm in height, allowing dense rack layouts without requiring excessive panel space. Average power draw is only 5.1 W, which helps limit cabinet heat rise during continuous operation. A task cycle of 1 ms allows rapid evaluation of safety logic, while the backplane supports deterministic data exchange at a network transfer rate of 100 Mbit/s. Via the POWERLINK interface, the module can be installed up to 100 m from the hub device without repeaters while maintaining full bandwidth on shielded twisted-pair cable.

The fieldbus layer refreshes safe process data every 20 ms, and the controller architecture is certified to the performance level of PL e. It also meets Safety Category Cat. 4 and system integrity level SIL 3, which supports use in applications that require very high stop reliability. One master can coordinate up to 100 safety nodes, and peer communication is available for as many as 10 controllers. This arrangement supports distributed emergency-stop buttons, light curtains, and safe drives across large machines while keeping all connected devices on common timing constraints.

Cooling
Fanless
Degree Of Protection
IP20
Depth
75 mm
Fieldbus Cycle Time
20 ms Max.
Height
99 mm
Interface
POWERLINK
Line Length
100 m Max.
Peer Communication
10 Controllers Max.
Performance Level
PL e
Power consumption
5.1 W
Safety Category
Cat. 4
Sil Class
SIL 3
Supported Safety Nodes
100 Max.
Task Cycle Time
1 ms
Transfer Rate
100 Mbit/s
Width
87.5+0.2 mm

Frequently Asked Questions about X20SL8011:

Q: What is the maximum fieldbus cycle time of the X20SL8011 module?

A: The X20SL8011 module supports a maximum fieldbus cycle time of 20 milliseconds, enabling timely data exchange in automation networks.

Q: Which communication interface is available on the X20SL8011?

A: This module uses the POWERLINK interface, allowing for reliable real-time communication in fieldbus applications.

Q: What is the data transfer rate of the X20SL8011 module?

A: The X20SL8011 offers a transfer rate of 100 Mbit/s for efficient data transmission.

Q: What is the maximum line length supported by the X20SL8011?

A: The maximum supported line length for this model is 100 meters, accommodating flexible installation distances.

Q: What safety ratings does the X20SL8011 module comply with?

A: This module belongs to performance level PL e and safety category Cat. 4, corresponding to SIL 3, supporting advanced functional safety requirements.


Internal Product Review

  • ‘‘The X20SL8011 is a B & R Automation safety fieldbus I/O module built for POWERLINK networks at 100 Mbit/s. A 1 ms task cycle time and SIL 3 classification give the module excellent responsiveness and confidence in demanding safety applications. PL e and Cat. 4 ratings make the unit an excellent fit for high-integrity machine safety architectures.’’