The X20PD0016 from B & R Automation is a module with mechanical spacing of 12.5+0.2 mm and diagnostics capabilities for module run/error and fuse monitoring. As part of the X20 Series, it operates at a nominal input voltage of 24 VDC -15% / +20% and consumes 0.12 W bus power. This module can handle permissible contact loads of 10 A.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

X20PD0016 is a potential distributor module. It works with X20 PLCs from B & R Automation. The module provides five ground connections and five 24 Volts DC connections at the terminals. An external supply is required. As there is no connection to internal I/O, the module only distributes an external supply for the electronics and load supply. The external supply is routed to the terminal connections via a field-replaceable microfuse. The PLC CPU can monitor the fuse and the external 24 Volts DC supply. Two LED indicators provide information about the module's operating state and its status. Power consumption of the bus on the X20PD0016 module is 0.12 Watts. Power consumption of the external I/O is 1.15 Watts. The module is certified by CE, KC, UL, ATEX and EAC.

The integrated fuse is a slow-blow fuse with 6.3 Amps current rating. It can be replaced in the field. To replace a defective fuse, the first required step is to remove the fuse cover with a screwdriver, slide out the defective fuse and push in the new fuse. Nominal output voltage of the X20PD0016 module is 24 Volts DC. The permissible contact load is 10 Amps. Both horizontal and vertical mounting positions are allowed. One terminal block with part number X20TB12 and one bus module with part number X20BM11 must be ordered separately. In addition to monitoring of the LED indicators, the module can be monitoring via software. The working temperature, when mounted horizontally, is -25 to 60 degrees Celsius and -25 to 50 degrees Celsius when mounted vertically. Up to 2000 meters, the module can be used without any required reduction in the ambient temperature.

Bus Power Consumption
0.12 W
Diagnostics
Module run/error, Fuse monitoring
External I/o Power Consumption
1.15 W
Mechanical Spacing
12.5+0.2 mm
Nominal Input Voltage
24 VDC -15% / +20%
Nominal Output Voltage
24 VDC, ground
Operating Temperature, Horizontal
-25 to 60 degrees C
Operating Temperature, Vertical
-25 to 50 degrees C
Permissible Contact Load
10 A
Reverse Polarity Protection
No
Status Indicators
Operating state, module status

Frequently Asked Questions about X20PD0016:

Q: What is the maximum altitude without derating?

A: The maximum permitted altitude without derating is 2000 meters.

Q: What is the operating temperature?

A: The operating temperature for vertical mounting is -25 to 50 degrees Celsius.

Q: What are the mounting orientations?

A: The module can be mounted in the vertical and horizontal orientations.

Q: What is the protection rating?

A: The protection rating is IP20.

Q: How many slots are occupied on CAN I/O?

A: One digital slot is occupied on CAN I/O.