Internal Product Review

The 2DO710.6 is a B & R Automation System 2010 controller output module with 8 change-over and 8 normally open outputs. Single channel isolation and a 2800 VAC isolation test voltage support dependable switching performance in industrial control assemblies. A mechanical contact life of 5 × 10^6 cycles makes this module an excellent choice for long-service applications.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The 2DO710.6 relay output card is a discrete output module produced by B&R Automation for the System 2010 Controllers series. It installs in a System 2010 backplane and switches field loads such as contactors, solenoids, and indicator lamps under PLC control. Galvanically isolated channels allow the card to translate low-level logic commands into mains-level signals for industrial actuators while separating the controller electronics from field circuits.

The relay arrangement includes 8 changeover contacts and 8 normally open contacts, allowing the module to operate both make-and-break circuits from the same board. Each relay supports a rated voltage of 30 VDC or 240 VAC and a rated current of 4 A, so branch protection and field wiring must suit these limits. Under light-signal conditions, the dry contacts have a resistance of only 100 mΩ at 6 VDC and 100 mA, minimizing voltage drop across sensitive loads. A switching request reaches the field terminals after an 13 ms output delay that accounts for relay transit time. Channel separation withstands an isolation test of 2800 VAC for one minute, protecting the controller electronics from voltage differences between field circuits.

The board draws 8 W from the external supply, while its logic consumes an additional 7 W internally, which must be considered when calculating cabinet heat dissipation. Across all relays, the card permits a 64 A total output current when the application observes the ΣIn² ≤ 400 load-sum limit that controls thermal rise in the common conductor. The minimum switching load is 5 VDC at 1 mA, while the contacts can interrupt voltages up to 125 VDC or 264 VAC and withstand transients of 460 V. Electrical endurance reaches 1 × 10⁵ operations at 8 A and 230 VAC, while the mechanical elements last 5 × 10⁶ cycles regardless of the connected load. Single-channel isolation confines an output fault to the affected relay instead of exposing the remaining channels to the same field-circuit condition.

Contact Resistance
100 mΩ @ 6 VDC / 100 mA
Electrical Life At 8 A, 230 Vac
1 × 10^5 cycles
External Power Draw
8 W
Internal Power Draw
7 W
Isolation Test Voltage
2800 VAC for 1 min
Isolation Topology
Single channel isolation
Load Sum Limit
ΣIn² ≤ 400
Max Peak Voltage
460 V
Max Switching Voltage
125 VDC / 264 VAC
Mechanical Contact Life
5 × 10^6 cycles
Min Switching Voltage
5 VDC @ 1 mA
Output Configuration
8 change-over; 8 normally open
Output Delay
13 ms
Rated Current
4 A
Rated Voltage
30 VDC / 240 VAC
Total Output Current
64 A

Frequently Asked Questions about 2DO710.6:

Q: What is the rated output voltage for the 2DO710.6 controller?

A: The 2DO710.6 controller supports a rated voltage of 30 VDC or 240 VAC on its outputs.

Q: How many outputs and what type are available on the 2DO710.6?

A: This unit has an output configuration of 8 change-over and 8 normally open contacts.

Q: What is the maximum total output current allowed for the 2DO710.6?

A: The maximum total output current for this device is 64 A.

Q: What is the electrical life expectancy of the 2DO710.6 at 8 A and 230 VAC?

A: The controller's electrical life at 8 A, 230 VAC is rated for 100,000 cycles.

Q: What is the isolation test voltage rating for the 2DO710.6 controller?

A: An isolation test voltage of 2800 VAC for 1 minute is specified for the 2DO710.6.