The B & R Automation 2CP200.60-1 is a controller from the System 2010 Controllers series, equipped with 2 MBytes of system RAM and dual-port RAM of 128 KBytes. It features isolated CAN, RS232, and RS485/RS422 interfaces, as well as 2 x 4 KB of cache memory. The controller requires two slots for installation and has network-capable RS485/RS422 and CAN ports.
Internal Product Review
The 2CP200.60-1 is a B & R Automation System 2010 controller with 2 MByte system RAM and 128 KByte dual-port RAM. Isolated RS232 and RS485/RS422 interfaces give the controller dependable serial connectivity for legacy and distributed equipment. A CAN-capable network port adds valuable integration range, making the controller a strong choice for compact industrial control platforms.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The 2CP200.60-1 central processing module is produced by B & R Automation and belongs to the System 2010 Controllers series. As a plug-in CPU card for compact PLC racks, it executes user programs, manages memory resources, and coordinates the fieldbus interfaces that link remote I/O and drive hardware. Within an automation cell, the unit provides deterministic task scheduling, making it the focal point for machine sequence control, data handling, and supervisory communication.
This processor carries 2 x 4 KB of cache that accelerates instruction fetches and variable access, reducing latency in time-critical logic sections. Main volatile storage is provided by 2 MByte of system RAM, allowing sizable PLC code blocks and real-time data arrays to run concurrently. A dedicated dual-port memory of 128 KByte supports high-speed handshaking between the CPU and the local backplane bus without occupying the main processor cycles. With a thermal budget of 20 W, the card stays within normal cabinet convection limits, so no separate blower is necessary. The controller occupies 2 slots in a System 2010 rack, which is an important layout consideration when planning multi-module arrangements.
For field connectivity, the module integrates one isolated CAN interface, one isolated RS232 interface, and one isolated RS485/RS422 interface. The galvanic isolation on each port prevents ground loops when nodes are at different potentials, which is a frequent issue in long cable installations. Combined, these links provide the RS485/RS422 + CAN network capability required for distributed inverter drives, operator terminals, and sensing expansions. Non-volatile application memory is ordered separately, letting the OEM select the EEPROM or flash capacity that matches program size while retaining code through power cycles. Because expansion unit use is not supported, all peripherals must connect through the built-in buses.