2AT610.6/Z

Ask for Availability

Preparing your secure checkout page...

The 2AT610.6/Z is a 2010 temperature measuring Analog Input Module with 16 differential inputs for J, L, and K thermocouples, covering -200 to +1300 C. C-UL-US listed, it pairs with BP200, BP201, or BP210 base plates. Inputs, arranged in four groups of four, handle -15 mV to +55 mV nominally, with -20 V to +20 V allowed. It features a Bessel low pass filter (8 Hz), >1 M1/2 resistance, and supports various measurement times per channel. Internal resolution exceeds 14 bits, with 0.1C output resolution. The module includes status LEDs and consumes minimal power.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The 2AT610.6/Z is a temperature measuring module of the year 2010, which is an Analog Input Module, and it has got 16 differential inputs for the type J, L, and K thermocouples over a range of -200 to +1300 C. This module is listed by C-UL-US and can be used with base plate modules BP200, BP201, or BP210 but terminal blocks need to be ordered separately. It has got 16 inputs arranged in four groups, each having four channels. The input signal ranges between nominally -15 mV to +55 mV with an allowable range of -20 V to +20 V. Differential input resistance is greater than one Mega 1/2 while inputs are filtered through Bessel low pass 2nd order filter having a cutoff frequency of 8 Hz.

For DC, common mode rejection is better than or equal to 80 dB, whereas at 50Hz, it stands at a minimum of 75dB. The module supports maximum modulation ~50V compared against ground and between electrically isolated groups with common mode control ~9V between channels within the group. Electrical isolation exists between input & PCC, combined group1&3, and combined group2&4, but not inside individual groups.

Measurement procedure involves voltage/frequency converter integration where adjustable measurement times per channel are set at either 20msec, 16.67msec, 10ms, or 8.33ms. Internal resolution surpasses 14 bits; internally quantized around 2.936uV with output resolution being 0.1C for temperature measurement. The module incorporates internal reference junctions that determine temperatures separately for each channel with accuracy ~4C across the working range & typically +3C/-1C at 25C. Status indicators include: terminal ok (red), RUN LED (green) plus ten yellow status LEDs. Operation modes are AT600 compatible (standard setting) as well as AT610.8W power is consumed by the module at most while its dimensions are 285mm in height, 40mm in width & 185mm in depth.

Allowable Input Signal Range
-20 V to +20 V
Base Plate Module Compatibility
BP200, BP201, BP210 (terminal blocks ordered separately)
Certification
C-UL-US listed
Differential Input Resistance
Greater than 1 M1/2
Input Arrangement
4 groups, each with 4 channels
Module Type
Analog Input Module
Nominal Input Signal Range
-15 mV to +55 mV
Number of Inputs
16 differential inputs
Temperature Range
-200 to +1300 C
Thermocouple Types Supported
J, L, K

Frequently Asked Questions about 2AT610.6/Z:

Q: What types of thermocouples are supported by the 2AT610.6/Z module, and what is the temperature range?

A: The 2AT610.6/Z module supports type J, L, and K thermocouples, with a temperature measurement range of -200 to +1300 C.

Q: How many inputs does the 2AT610.6/Z module have, and how are they arranged?

A: The module has 16 differential inputs, arranged in four groups of four channels each.

Q: What are the input signal and voltage range specifications for the 2AT610.6/Z module?

A: The input signal ranges nominally from -15 mV to +55 mV, with an allowable range of -20 V to +20 V. The differential input resistance is greater than one Mega 1/2.

Q: What are the electrical isolation features of the 2AT610.6/Z module?

A: Electrical isolation exists between the input and PCC, between combined group1&3 and combined group2&4, but not within individual groups. The module supports maximum modulation of ~50V compared against ground and between electrically isolated groups, with common mode control of ~9V between channels within a group.

Q: What are the measurement resolution and accuracy specifications for the 2AT610.6/Z module?

A: The module has an internal resolution surpassing 14 bits, with quantization around 2.936uV and an output resolution of 0.1C for temperature measurement. The internal reference junctions have an accuracy of ~4C across the working range and typically +3C/-1C at 25C.


Internal Product Review

  • ‘‘The 2AT610.6/Z, a 2010 temperature measuring module, is an Analog Input Module designed with 16 differential inputs for J, L, and K thermocouples, covering a range from -200 to +1300 C. C-UL-US listed for safety, it is compatible with BP200, BP201, and BP210 base plates, with terminal blocks ordered separately.’’