The B&R 2AT610.6 analog input module, introduced in 2010 for the B&R System 2010, specializes in temperature measurement using thermocouples. With 16 differential inputs for thermocouple types L, J, K and a wide range from -200 to +1300 C, it meets precise temperature control needs across various industrial applications.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The B&R 2AT610.6 analog input module is part of the B&R System 2010 and designed for temperature measurement with thermocouples. It was published in 2010 and has 16 differential inputs for thermocouple types L, J, K and a measuring range of -200 to +1300 C. Thus it can be used in various industrial fields where precise temperature control is required.

The module consists of four groups, each comprising four channels, which are galvanically isolated from the PCC (potential common conductor) as well as from other groups, but not among themselves. Therefore, safety requirements are met while noise immunity is increased. The nominal input signal range for these thermocouples lies within -15 to +55 mV differentially; besides, their differential input resistance exceeds 1 MOhm thereby ensuring accurate measurements under normal conditions. Additionally, there is a Bessel low pass 2nd order input filter with an 8 Hz cut-off frequency in the 2AT610.6 module; thus, it significantly reduces noise so that stable readings become possible even in noisy environments like electrically dense cabinets or near frequency converters, etcetera. DC common mode rejection ratio of this device reaches up to 80 dB, meanwhile, its AC common mode rejection ratio equals 75 dB at f=50Hz. Also, maximum modulation relative to ground is ~50 V, whereas between electrically isolated groups ~50 V.

The measurement process performed by means of the 2AT610.6 involves an integrated voltage-to-frequency converter whose adjustable measurement times per channel are: Tm = 20 ms (standard), Tm = 16.67 ms, Tm = 10 ms, Tm = 8.33 ms. The internal resolution exceeds fourteen bits, which corresponds to 2.936 uV per bit for voltage quantities or 0.1 C per bit in case of temperature values, thus enabling highly accurate readings to be taken.

Allowed input signal
-20 to +20 V
C-UL-US listed
Yes
Channel groups
4 (1-4, 5-8, 9-12, 13-16)
Common mode rejection (50 Hz)
75 dB
Common mode rejection (DC)
80 dB
Differential input resistance
>1 MΩ
Filter cutoff frequency
8 Hz
Input filter
Bessel 2nd order low-pass
Manufacturer
B&R
Model number
2AT610.6
Nominal input signal
-15 to +55 mV
Number of inputs
16 differential (thermocouples)
Supported base plate modules
BP200, BP201, BP210

Frequently Asked Questions about 2AT610.6:

Q: What types of inputs does the B&R 2AT610.6 Analog Input Module support?

A: The module supports 16 differential inputs designed for thermocouples of types L, J, and K, with a wide measuring range from -200 to +1300 C, making it suitable for precise temperature measurement in various industrial applications.

Q: Does the B&R 2AT610.6 module provide electrical isolation?

A: Yes, the module provides galvanic isolation between each of the four groups of inputs and the PCC (Potential Common Conductor), ensuring safety and reducing noise interference. However, there is no isolation between individual channels within the same group.

Q: How does the B&R 2AT610.6 module handle noise in input signals?

A: The module includes a Bessel low pass 2nd order input filter with an 8 Hz cutoff frequency, significantly reducing noise and improving signal stability. It also features a DC common mode rejection ratio of up to -80 dB and an AC common mode rejection ratio of -75 dB at 50 Hz, enhancing noise immunity in electrically dense environments.

Q: What is the measurement resolution and accuracy of the B&R 2AT610.6 module?

A: The module offers an internal resolution exceeding fourteen bits, translating to approximately 2.936 uV per bit for voltage measurements or 0.1 C per bit for temperature values. It ensures highly accurate readings across a wide range of temperatures.

Q: What are the adjustable measurement times available in the B&R 2AT610.6 module?

A: The module features an integrated voltage-to-frequency converter with adjustable measurement times per channel, offering settings such as 20 ms (standard), 16.67 ms, 10 ms, and 8.33 ms, allowing flexibility in data acquisition speed according to application requirements.


Internal Product Review

  • ‘‘The B&R 2AT610.6 Analog Input Module is a crucial component of the B&R System 2010, tailored for temperature measurement with thermocouples. ’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo