The B & R Automation 2AT600.6 is part of the System 2010 Controllers series and supports 16 input channels. It features a conversion time of 20 milliseconds and a maximum cycle time of 235 milliseconds. The controller is compatible with L-type FeCuNi sensors following the DIN 43710 standard, and includes a shield resistor of 100 Ohms.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
B&R Automation manufactures the 2AT600.6, a temperature input module for the System 2010 Controllers series. Designed for thermocouple integration, the card converts millivolt signals into engineering units so the controller CPU can respond to thermal conditions in furnaces, dryers, or packaging sealers. By slotting this module into the System 2010 backplane, the control system receives direct, isolated temperature feedback without external signal conditioners, which helps keep cabinet layouts simpler and reduces extra interface hardware. This arrangement also lets multiple measurement points be processed inside the controller platform instead of through separate temperature conversion devices.
Each channel is scanned with a conversion time of 20 msec, so the analog-to-digital converter produces a new reading every twentieth of a second. With 16 available inputs, a single card can monitor multiple heating or cooling zones while leaving other slots free for additional field signals. A complete block update is finished within a maximum cycle time of 235 msec, which gives the control task a predictable refresh interval for temperature processing. Temperature data are delivered with a resolution of 0.1 °C, allowing tighter control of heater switching behavior and narrower process dead bands. When sensor voltage exceeds the overrange threshold of +750.0 °C, the module flags an alarm instead of rolling over, which helps prevent misleading values from being passed to the application.
The lower detection limit is -50.0 °C, so sub-ambient processes can still be monitored. Type L thermocouples made from FeCuNi in accordance with DIN 43710 are accepted directly, and internal linearization removes the need for external lookup tables during signal processing. A built-in 100 Ω shield resistor on every channel helps reduce common-mode interference that can appear over long cable runs. This improves measurement stability in electrically noisy installations where sensor wiring is routed near switching equipment or other control conductors.
Frequently Asked Questions about 2AT600.6:
Q: What is the conversion time of the 2AT600.6 controller?
A: The 2AT600.6 controller has a conversion time of 20 milliseconds, enabling prompt data processing from its inputs.
Q: How many input channels does the 2AT600.6 provide?
A: This model features 16 available input channels for sensor connections or signal processing.
Q: Which sensor type and standard are compatible with the 2AT600.6 controller?
A: The 2AT600.6 is designed to work with type L sensors according to the DIN 43710 standard.
Q: What is the temperature resolution available on the 2AT600.6?
A: Temperature readings can be resolved down to 0.1 °C on this controller, allowing for precise measurements.
Q: What are the temperature measurement ranges for the 2AT600.6 controller?
A: The overrange and underrange thresholds for this unit are +750.0 °C and -50.0 °C, respectively.