The 8I74S200075.010-1 is a cylindrical steel inverter with a length of 75.0 mm and a hardness range of HRC 40-45. Manufactured by B & R Automation, it is part of the 8I7 ACOPOS Inverters series and weighs 0.32 kg. The inverter features temperature resistance up to 350°C and a tolerance of ±0.010 mm.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The 8I74S200075.010-1 Frequency Inverter is built for robust and reliable drive control in industrial applications. It features a power rating of 2.0 kVA and supports both 200 VAC and 240 VAC input voltages. It ensures efficient motor operation under varying conditions with compact construction, integrated braking and digital output options.
This 8I74S200075.010-1 frequency inverter provides an apparent power of 2.0 kVA at 240 VAC. The maximum rated short circuit current at the connection point is 1 kA. The inrush current is limited to a maximum of 9.6 A. The unit draws 10.1 A at 200 VAC and 8.5 A at 240 VAC. The power loss at rated load and rated clock frequency is 51 W. It offers a rated motor output current of 4.8 A and can handle transient currents up to 7.2 A for 60 seconds and 7.9 A for 2 seconds. The output current remains stable without derating up to 50 °C ambient temperature at a nominal clock frequency of 4 kHz. The derating is required based on altitude at 1 % per 100 meters above 1000 meters sea level. The inverter includes an integrated dynamic braking system with external resistor support that requires a minimum resistance of 40 ohms.
The 8I74S200075.010-1 frequency inverter from B & R Automation includes a 24 V DC logic supply that consumes up to 1.1 A. One digital output is available in this model that operates at 24 VDC nominal voltage and up to 30 VDC maximum. This digital output supports both source and sink configurations and can handle a maximum current of 100 mA with a 2 ms sampling time. It includes two relay outputs capable of switching up to 30 VDC or 250 VAC.
Frequently Asked Questions about 8I74S200075.010-1:
Q: Can the 8I74S200075.010-1 inverter handle transient current surges without stability issues?
A: Yes, this inverter safely handles transient currents up to 7.2 A for 60 seconds and 7.9 A for 2 seconds. It maintains stable output without derating up to 50 °C ambient temperature.
Q: Will the 8I74S200075.010-1 frequency inverter require derating at higher altitudes?
A: Yes, derating begins above 1000 meters with a 1% reduction per 100 meters. This adjustment ensures consistent performance under lower air density conditions.
Q: Does the 8I74S200075.010-1 inverter include dynamic braking for high-load deceleration?
A: It includes an integrated dynamic braking system with external resistor support. The external braking resistor must have a minimum resistance of 40 ohms.
Q: How does the 8I74S200075.010-1 model manage input current at different voltages?
A: At 200 VAC, the inverter draws 10.1 A, while at 240 VAC it draws 8.5 A. Inrush current is capped at a maximum of 9.6 A.
Q: Are the digital and relay outputs on the 8I74S200075.010-1 suitable for flexible control schemes?
A: Yes, it includes one digital output supporting both source and sink modes up to 100 mA. It also has two relay outputs that switch 30 VDC or 250 VAC reliably.