8166T400150.0P-000
Wake Industrial LLC is not an authorized distributor of this product.
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The 8166T400150.0P-000 by B & R Automation is part of the 8I6 ACOPOS Inverters series and is constructed from a durable Titanium Alloy (Ti6Al4V). It boasts a tensile strength of at least 950 MPa, a polished surface finish, and a diameter of 15.0 mm. With excellent corrosion resistance, it meets the AMS 4928 specification.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The 8166T400150.0P-000 ACOPOS inverter is designed in order to ensure the motor is working properly. The inverter transforms the electrical input into a controlled motor output. It has the seals of approval from KC, CE, UKCA, and cULus E225616. The 1.5 kW or 2 HP motor power rating.
With a nominal output current of 4.1 A and a maximum transient current of 6.2 A for 60 seconds, the 8166T400150.0P-000 ACOPOS inverter is an efficient choice. The inverter operates with a nominal clock frequency of 4 kHz. A frequency range of 0.1 to 599 Hz is available for output. At normal clock frequency and up to 50°C ambient temperature, the inverter does not necessitate derating of continuous output current. The inverter is necessary to reduce the continuous output current by 1% for every 100 meters when the installation is done over 1000 meters elevation. A clock frequency range of 2 kHz to 16 kHz is supported by the inverter. For motors with a rated torque of up to 170 percent, a brake resistor can be used to generate braking torque. The maximum length of a motor cable that can be shielded is 50 meters, and the maximum length of a non-shielded cable is 100 meters.
In order to ensure that motors run efficiently, the 8166T400150.0P-000 inverter adheres to standards for power conversion equipment. The inverter allows for a broad range of control over the motor's speed, with a maximum output frequency of 599 Hz. A further feature that guarantees steady functioning is its nominal clock frequency of 4 kHz. All operational and installation circumstances must comply with the designated criteria. The integrity of the system is maintained by the proper use of certified components.
Frequently Asked Questions about 8166T400150.0P-000:
Q: How does the ACOPOSinverter 8166T400150.0P-000 braking resistor help in motor performance control?
A: The braking resistor allows dissipation of excess energy during rapid deceleration. It achieves braking torque up to 170% of motor torque, enhancing stopping performance and improving system safety and responsiveness.
Q: Why does the ACOPOSinverter 8166T400150.0P-000 need current derating above 1000 meters installation elevation?
A: At elevations above 1000 m, air density decreases, affecting cooling efficiency. Current derating (1% per additional 100 m) maintains optimal inverter operation by preventing overheating under reduced cooling conditions.
Q: Does ACOPOSinverter 8166T400150.0P-000 support both shielded and non-shielded motor cables for installation?
A: Yes, it supports shielded cables up to 50 m and non-shielded cables up to 100 m. Shielded cables reduce electrical interference, ensuring stable performance and protecting sensitive electronic components.
Q: Do clock frequencies affect the continuous output current of the ACOPOSinverter 8166T400150.0P-000?
A: Yes, clock frequencies other than 4 kHz affect the inverter current capacity. Higher frequencies may cause inverter heating, requiring derating of current based on ambient temperature to ensure operational reliability.
Q: How does ACOPOSinverter 8166T400150.0P-000 handle transient current spikes during motor startups?
A: It handles transient current spikes up to 6.2 A for 60 seconds. This transient capacity accommodates increased startup currents, enabling smooth motor acceleration without inverter overload or performance degradation.