4.95 based on 203 reviews

🙶 Wake was very helpful in getting us a servo motor and drive for our tube mill line. This was the first tim... 🙷

80VD100PD.C088-01 B & R Automation

In-Stock, Ships 3-5 Days
No Hidden Fees Rush or Credit Card
No Tariffs On US Orders

Internal Product Review

The 80VD100PD.C088-01 is a B & R Automation inverter module with IP20 protection and a 24 VDC ±25% CPU supply. Dual motor connections and 8 ARMS nominal current make the unit well suited for steady multi-axis drive service. A 20 kHz controller frequency is a strong performance advantage for precise inverter control.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The 80VD100PD.C088-01 inverter module is built by B&R Automation for the 80VD Inverter Modules series. It is a compact drive stage that converts a shared DC link into controlled three-phase power for two synchronous or induction motors, integrating current measurement, position feedback evaluation, and pulse-width modulation in one housing. By combining these functions, the unit supplies torque, speed, and position control to machinery such as pick-and-place gantries, packaging stations, and small conveyor axes within automated lines. It mounts on a DIN rail inside a central cabinet and communicates with the main PLC over the X2X real-time bus, allowing scalable multi-axis arrays without separate drive controllers.

Internally, the module’s digital signal processor samples phase currents with a 12-bit converter, and closed-loop algorithms execute at 20 kHz to minimize control latency. Control electronics are powered from a 24 VDC ±25% service rail, while the power section is stabilized by 940 µF of DC-bus capacitance that absorbs regeneration peaks. Two SinCos encoder inputs are provided, and each channel receives 5 V ±5% excitation so that absolute position can be resolved at high resolution. The gate drive produces a nominal switching frequency of 5 kHz. The thermal design allows each motor channel to supply up to 10.6 A RMS / 15 A peak for short intervals without exceeding junction temperature limits. Motor leads may extend up to 25 m, and both outputs are available through dedicated screw terminals.

The drive body carries an IP20 protection rating, so it requires installation inside a closed panel but needs no additional finger guards. During startup, an active precharge circuit limits the maximum surge current to 10 A, protecting upstream fuses. Continuous operation is rated at 8 A RMS, and dynamic monitoring disconnects the stage if the DC link rises above 95 VDC. Shutdown also occurs when the voltage drops below 18 VDC to avoid uncontrolled conduction. An isolation barrier separates the logic and power sections to maintain signal integrity. Embedded temperature sensors allow controlled derating before thermal thresholds are reached, supporting dense multi-axis assemblies in shared cabinets.

Adc Resolution
12-bit
Controller Frequency
20 kHz
Cpu Supply Voltage
24 VDC ±25%
Dc Bus Capacitance
940 µF
Degree Of Protection
IP20
Encoder Inputs
2
Encoder Supply Voltage
5 V ±5%
Encoder Type
SinCos
Inrush Current
10 A Max
Max Current Per Motor
10.6 ARMS / 15 APeak
Max Motor Line Length
25 m
Motor Connections
2
Nominal Current
8 ARMS
Nominal Switching Freq
5 kHz
Overvoltage Cutoff
>95 VDC
Undervoltage Cutoff
<18 VDC

Frequently Asked Questions about 80VD100PD.C088-01:

Q: How many encoder inputs and what type does the 80VD100PD.C088-01 module support?

A: This unit offers two SinCos encoder inputs for accurate position feedback.

Q: What is the longest motor line length allowed with the 80VD100PD.C088-01?

A: The maximum motor line length supported is 25 meters for this inverter module.

Q: What is the maximum current per motor supported by the 80VD100PD.C088-01?

A: The 80VD100PD.C088-01 provides a maximum current output of 10.6 ARMS, peaking at 15 A.

Q: What CPU supply voltage is required for the 80VD100PD.C088-01 module?

A: This model operates with a CPU supply voltage of 24 VDC with a ±25% tolerance.

Q: What degree of protection is provided by the 80VD100PD.C088-01?

A: The 80VD100PD.C088-01 inverter module is rated for IP20 degree of protection.