5AC600.UPSI-00 B & R Automation
Wake Industrial LLC is not an authorized distributor of this product.
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
Current response time:
4 Minutes
42 Seconds
The 5AC600.UPSI-00 is a CNC addon module from the 5AC CNC Addon Modules series by B & R Automation. It features deep discharge protection with a threshold of 10 V and provides a maximum charging current of 0.5 A. The module offers a power failure bypass lasting 20 minutes at 150 W and consumes a maximum of 7.5 W.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The 5AC600.UPSI-00 is an uninterruptible power-supply interface module produced by B&R Automation and supplied within the 5AC CNC Addon Modules series. It bridges brief power outages so connected CNC controllers can finish active machine cycles and store process data safely before the control system shuts down. By monitoring its 24 V DC input and an external backup battery, the module automatically switches between sources and shields the load from voltage dips that would otherwise interrupt motion control electronics. This operating method helps prevent abrupt resets that can leave axes in an undefined state after a supply disturbance.
The unit provides deep discharge protection to keep the backup battery from dropping to damaging levels. It returns from battery to supply once the sensor detects 13 V at the battery input, and a separate transfer point of 15 V on the input line makes sure charging begins only after the primary supply has recovered. During recharge, the controller limits current to 0.5 A, reducing cell heating and helping preserve battery service life. Internal circuitry draws no more than 7.5 W, leaving most of the stored energy available for the connected control hardware during backup operation.
When battery voltage falls to 10 V, the load is disconnected to avoid irreversible cell damage. A charged battery can maintain bypass power for 20 minutes at 150 W, which is typically enough time for a controlled machine stop and secure data handling. Because there is no short-circuit protection, external fusing on the DC line is required to protect the wiring and connected equipment. The module is intended to support a controlled shutdown of connected electronics during brief supply loss, rather than to keep the machine in normal production until battery capacity is exhausted.
Frequently Asked Questions about 5AC600.UPSI-00:
Q: Does the 5AC600.UPSI-00 provide deep discharge protection for its battery?
A: The 5AC600.UPSI-00 features deep discharge protection to safeguard the battery during extended use.
Q: What is the maximum power consumption of the 5AC600.UPSI-00 module?
A: Its maximum power consumption is 7.5 watts during operation.
Q: What is the maximum charging current supported by the 5AC600.UPSI-00?
A: The module has a maximum charging current of 0.5 amps.
Q: How long can the 5AC600.UPSI-00 supply power during a failure at 150 W?
A: It can bypass a power failure for up to 20 minutes at 150 watts.
Q: Is the 5AC600.UPSI-00 designed to be resistant to short circuits?
A: The 5AC600.UPSI-00 is not short-circuit proof.