4XP0070.00-00B
Wake Industrial LLC is not an authorized distributor of this product.
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
-
Available
The 4XP0070.00-00B control interface by B&R is a top-tier solution for industrial automation. It features an X2X slave interface with a 4-pin M12 connector, supporting reliable connectivity up to 100 meters with electrical isolation. The interface includes six illuminated ring keys and an emergency stop button for enhanced safety.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The 4XP0070.00-00B control interface is an advanced answer for industrial computerization that meets the most elevated quality and wellbeing measures. For this reason, it is certified with CE and UL (cULus E115267) as an industrial control device thus ensuring compliance with international standards. The 4XP0070.00-00B utilizes X2X slave interface with a 4-pin M12 connector which supports internal bus supply and electrical insulation enabling reliable connection up to 100 meters apart between stations. It also has six B&R illuminated ring keys in red, green, yellow and white which are visible under different lighting conditions for easy use.
To quicken reaction during emergencies two normally closed contacts of Rafix 22FS 1.30.273.511/0300 are used in the emergency stop feature which enhance safety and reliability within industrial environments. With a nominal voltage of 24 VDC, the maximum power consumption of the 4XP0070.00-00B is eight watts while supporting voltage range between eighteen to thirty volts direct current along with a current consumption up to 320 mA which ensures use of energy resourcefully. On the other hand the device provides IP65 protection at both front side and back side coupled with UL50 Type4X protection suitable for indoor use thereby making it applicable in harsh conditions encountered by industries..
The temperature range in which the 4XP0070.00-00B can operate lies from zero degrees Celsius (+0C) up to fifty degrees Celsius (+50C) whereas its storage or transportation should be done within minus twenty (-20C) degrees Celsius plus sixty degrees Celsius (-20C). In relative humidity conditions not exceeding forty degrees centigrade (^240C), non-condensing up to eighty five percent (85%) may be allowed but not more than seventy five percent (75%) when above that temperature. Additionally, it is designed to work at altitudes of up three kilometers above sea level while mechanically having anodized aluminum frame with glossy finish, polyester panel overlay as well galvanized sheet metal housing and these features make it heavy about six hundred grams (600g) thereby measuring seventy-seven millimeters wide by one hundred seventy-five millimeters high and eighty-six millimeter deep.
Frequently Asked Questions about 4XP0070.00-00B:
Q: What certifications does the 4XP0070.00-00B control interface have?
A: The 4XP0070.00-00B control interface is certified to CE and UL (cULus E115267) standards, ensuring it meets the highest quality and safety standards for industrial control devices.
Q: What are the main features of the 4XP0070.00-00B control interface?
A: This interface includes an X2X slave interface with a 4-pin M12 connector, supporting internal bus power supply and electrical insulation for reliable connections up to 100 meters apart. It features six B&R illuminated ring keys in red, green, yellow, and white for easy use under different lighting conditions, and a Rafix 22FS emergency stop button with two normally closed contacts for enhanced safety.
Q: What are the power requirements and consumption of the 4XP0070.00-00B control interface?
A: The device operates at a nominal voltage of 24 VDC with a maximum power consumption of 8 watts. It supports a voltage range of 18 to 30 VDC and has a current consumption of up to 320 mA, ensuring efficient energy use.
Q: What are the environmental protections and operating conditions for the 4XP0070.00-00B control interface?
A: The interface provides IP65 protection on both the front and back sides, along with UL50 Type 4X protection, making it suitable for indoor use in harsh industrial conditions. It operates within a temperature range of 0C to +50C and can be stored or transported in temperatures from -20C to +60C. It can function in relative humidity conditions up to 85% non-condensing at ^240C and up to 75% non-condensing at temperatures above 40C. It is also designed to work at altitudes up to 3000 meters above sea level.
Q: What are the physical dimensions and construction details of the 4XP0070.00-00B control interface?
A: The control interface measures 77 mm in width, 175 mm in height, and 86 mm in depth, weighing approximately 600 grams. It features an anodized aluminum frame with a glossy finish, a polyester panel overlay, and a galvanized sheet metal housing, ensuring durability and robust performance in demanding industrial environments.