The Vickers EHA-CON-201-A-20 is part of the EHA Power Supplies series and operates with a nominal supply voltage of 24 V DC, supporting a voltage range of 18 to 36 V DC. It delivers an output signal of ±10 V DC and supports input signal options of 0–10 V, 0–20 mA, and 4–20 mA. This power supply features IP20 protection, consumes 6 Watts, and can be mounted on a DIN EN 50022/50035 rail.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The EHA-CON-201-A-20 is a power supply and signal-conditioning module manufactured by Vickers for the EHA Power Supplies series. In automated machinery, the device furnishes regulated reference voltages and reproduces process command signals, while its built-in fault channel informs the controller when supply quality or internal parameters fall outside allowed limits. Using one compact board, it bridges the plant's low-voltage bus to proportional valves, sensors, and other field hardware that depend on stable excitation and clean command signals for repeatable machine response.
During operation, the unit draws from a nominal input of 24 V DC, yet it stays online anywhere within 18–36 V DC, absorbing typical bus dips without loss of regulation. Overall demand is just 6 W, which helps limit cabinet heating without adding much thermal load to the enclosure. Front-end jumpers allow selection between 0–10 V / 0–20 mA / 4–20 mA command formats, and the chosen option is converted internally to a precision, low-impedance ±10 V DC output for the downstream actuator. This conversion supports control accuracy because the outgoing rails are generated by regulated converters rather than passed directly from a noisy field signal.
The module supports continuous duty from 0 to 50 °C, while storage when unpowered can extend between −25 to 85 °C without component damage. The enclosure carries an IP20 rating and snaps onto a DIN EN 50022/50035 rail, which helps simplify installation alongside other control modules in a cabinet. Should an internal error occur, the device grounds its output and issues a dedicated fault-switching signal, which helps prevent unintended actuator movement. Auxiliary terminals provide a +15 V rail at 50 mA for sensor power and a +10 V reference at 5 mA for calibration tasks, and the design tolerates ±10% peak-to-peak ripple on the DC bus without disturbing these regulated outputs.
Frequently Asked Questions about EHA-CON-201-A-20:
Q: What is the required supply voltage for the EHA-CON-201-A-20 power supply?
A: This model operates on a nominal supply voltage of 24 V DC and accepts a supply range between 18 and 36 V DC.
Q: What input signal options does the EHA-CON-201-A-20 support?
A: The EHA-CON-201-A-20 is equipped with input signal options of 0–10 V, 0–20 mA, and 4–20 mA.
Q: What does the error output indicate on the EHA-CON-201-A-20?
A: The error output on this model provides a fault switching signal for monitoring output status.
Q: What happens to the output when a fault is detected on the EHA-CON-201-A-20?
A: On error detection, the output of the EHA-CON-201-A-20 is grounded for safety.
Q: How is the EHA-CON-201-A-20 power supply mounted?
A: The EHA-CON-201-A-20 is designed for DIN rail mounting according to DIN EN 50022 and DIN EN 50035 standards.