EEA-PAM-571-A-14 Vickers
- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Vickers EEA-PAM-571-A-14 is a power amplifier from the EEA-PAM Power Amplifiers series. It operates with a nominal input supply voltage of 24 V DC and can consume up to 40 watts of power. The amplifier has a mass of 0.22 kg and a maximum ambient temperature rating of 50 degrees Celsius.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The EEA-PAM-571-A-14 is a plug-in hydraulic valve power amplifier manufactured by Vickers for the EEA-PAM Power Amplifiers series. It converts low-level electrical commands into regulated solenoid current so proportional valves track pressure or flow instructions in automated machinery. Mounted on a DIN carrier board, the module integrates ramp generators and reference supplies that let PLCs drive hydraulic actuators while reducing shock during fast transitions.
Normal operation is based on an input of 24 V DC, and peak consumption reaches 40 W. The card derives an auxiliary rail of +15 V DC, 50 mA for external sensors. Voltage-mode set-points up to 10 V enter through a 47 kΩ path, while current-mode control runs to 20 mA with 100 Ω input impedance. A 6.8 kΩ enable line allows safety relays to remove drive instantly. Power disturbances of 4 Vp-p ripple are tolerated without output drift, and the circuit maintains 1.1 A of standing solenoid current when the command is zero.
The unit withstands ambient temperatures to 50 °C and weighs only 0.22 kg, fitting compact enclosures. Ramp time is adjustable down to 50 ms, enabling quick valve response while limiting hydraulic overshoot. Undervoltage protection disables the amplifier below 19 V DC to prevent erratic operation. Separate +10 V DC and –10 V DC references at 5 mA each support bipolar potentiometers, and the voltage input impedance of 47 kΩ minimizes loading on control electronics. Together with the 6.8 kΩ enable resistance and the defined ripple tolerance, these features ensure consistent current delivery across the full electrical and thermal envelope.
Frequently Asked Questions about EEA-PAM-571-A-14:
Q: What is the required input supply voltage for the EEA-PAM-571-A-14 amplifier?
A: The EEA-PAM-571-A-14 accepts a nominal input supply voltage of 24 V DC.
Q: What is the maximum allowed ambient temperature for using the EEA-PAM-571-A-14?
A: This power amplifier supports a maximum ambient temperature of 50 °C during operation.
Q: What is the peak input power consumption of the EEA-PAM-571-A-14?
A: The maximum input power consumption for this unit is 40 W.
Q: What is the current command full scale for the EEA-PAM-571-A-14?
A: A full scale current command value on this device is 20 mA.
Q: At what voltage does the EEA-PAM-571-A-14 shut down due to undervoltage?
A: The undervoltage shutdown threshold is set at 19 V DC for this amplifier.