The EEA-PAM-568-D-32 is a power amplifier card manufactured by Vickers and is part of the EEA-PAM Power Amplifiers series. It features a supply voltage of 24 VDC and utilizes a DIN 41612 F48 Male card connector. The card offers a control supply output of +15 V and supports alarm outputs up to 50 mA with a 50 Ohm resistance.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The EEA-PAM-568-D-32 is a plug-in power amplifier card produced by Vickers for the EEA-PAM Power Amplifiers series. Installed in electro-hydraulic valve control racks, the board converts low-level command signals into driver currents that position proportional and servo valves within automated machinery. By combining signal scaling, ramp generation, and alarm reporting on a single printed circuit assembly, it simplifies closed-loop pressure or flow regulation tasks in industrial automation systems.
The module draws its logic energy from a nominal 24 VDC rail and returns a stabilized auxiliary output of +15 V, which can power external sensors or reference networks. Alarm circuitry is able to sink up to 50 mA through a built-in transistor stage; internal limiting by a 50 Ω resistor protects downstream indicators against short circuits. For voltage-driven commands, the front end presents an input impedance of 47 kΩ, allowing long cable runs without excessive loading on the controlling PLC or motion card. Together these parameters define the electrical boundary conditions for reliable valve actuation under fluctuating plant supply conditions.
Interface details further tailor the card to system integration needs. The enable line draws just 10 mA, so even low-power digital outputs can activate the drive stage. Feed-forward tuning is applied through a separate node with 6 kΩ impedance, letting designers superimpose open-loop corrections without disturbing the main feedback path. High-resolution transducers can be wired directly because the sensor voltage input reaches 1 MΩ, minimizing measurement error from divider loading. All terminations are consolidated on a DIN 41612 F48 male connector, which supports rapid module exchange and ensures that every signal pin remains keyed to its mating backplane position.
Frequently Asked Questions about EEA-PAM-568-D-32:
Q: What supply voltage does the EEA-PAM-568-D-32 power amplifier require?
A: The EEA-PAM-568-D-32 amplifier is designed for use with a 24 VDC supply voltage.
Q: What type of card connector does the EEA-PAM-568-D-32 utilize?
A: This model uses a DIN 41612 F48 Male connector for its card interface.
Q: What is the maximum current rating for the alarm output on the EEA-PAM-568-D-32?
A: The alarm output on the EEA-PAM-568-D-32 can handle a maximum current of 50 mA.
Q: What is the reference voltage range provided by the EEA-PAM-568-D-32?
A: The reference voltage output for this amplifier ranges from -10 V to +10 V.
Q: What is the control supply output voltage of the EEA-PAM-568-D-32?
A: The control supply output on this amplifier delivers +15 V for connected components.