The Vickers EEA-PAM-568-C-30 is part of the EEA-PAM Power Amplifiers series and has a nominal supply voltage of 24 VDC with a power requirement of 40 Watts. This amplifier uses a Eurocard form factor, features output short-circuit and reverse polarity protection, and offers a gain potentiometer and ramp potentiometer, each with 20 turns. Its control supply voltage is ±15 V and control supply current is 50 mA.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The EEA-PAM-568-C-30 is a slide-in power amplifier card manufactured by Vickers for the EEA-PAM Power Amplifiers series. Designed to occupy a standard Eurocard slot, it interfaces with proportional valve coils and converts low-level command references into regulated drive currents. Within an automation panel it modulates hydraulic actuators, giving the machine builder a compact means of managing motion profiles directly from PLC or analog controllers.
Its electronic section is supplied from a nominal system rail of 24 VDC, while the control stage uses a stabilized dual line of ±15 V at only 50 mA; this split arrangement separates load power from signal conditioning and limits noise on feedback loops. Overall consumption stays below 40 W, so cabinet thermal management remains uncomplicated. A gain trimmer with 20 turns gives fine resolution when matching valve stroke to command levels, and a separate 20-turn ramp potentiometer lets maintenance staff tune acceleration or deceleration without external devices. Output drive is guarded by built-in short-circuit protection, and an automatic overload reset clears fault conditions once the load is removed.
For motion profiles, the internal ramp generator spans from a minimum of 0.050 s to a maximum of 5 s, allowing gradual or rapid spool movement as required by the hydraulic circuit. The enable input presents a high impedance of 22 kΩ, so most PLC transistor outputs can activate the card without loading their power budgets. Reference sources may use the on-board ±10 V node or the constant 5 mA current output, eliminating the need for external signal conditioners. Should the supply drop toward 18 VDC the amplifier shuts down to protect connected solenoids; reverse-polarity diodes prevent damage if the rack wiring is misconnected. All functions stay active after a fault because ramp values, gain settings, and the automatic recovery logic restore normal operation without manual intervention.
Frequently Asked Questions about EEA-PAM-568-C-30:
Q: What is the nominal supply voltage required for the EEA-PAM-568-C-30 amplifier?
A: The nominal supply voltage for the EEA-PAM-568-C-30 power amplifier is 24 VDC.
Q: How does the EEA-PAM-568-C-30 handle overload situations?
A: This unit automatically resets in the event of an overload condition.
Q: What type of gain control does the EEA-PAM-568-C-30 amplifier provide?
A: You can set the gain using a 20-turn potentiometer for precise adjustments.
Q: Does the EEA-PAM-568-C-30 amplifier include output short-circuit protection?
A: The output features built-in short-circuit protection for safety.
Q: What is the maximum ramp time that can be set on the EEA-PAM-568-C-30 amplifier?
A: The amplifier supports a maximum ramp time setting of 5 seconds.