EEA-PAM-561-E-32 Vickers

In-Stock, Ships 3-5 Days

Preparing your secure checkout page...

The Vickers EEA-PAM-561-E-32 is part of the EEA-PAM Power Amplifiers series and operates on a nominal supply voltage of 24 VDC. It features a control supply output of +15 VDC and comes with a DIN 41612 F48 edge connector. The amplifier offers sensor input resistances of 100 ohms for current and 100 kiloohms for voltage.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The EEA-PAM-561-E-32 is a plug-in power amplifier card from Vickers in the EEA-PAM Power Amplifiers series. It slides into a 32-way industrial rack and drives proportional or servo hydraulic valves by conditioning command and feedback loops. Within automated machinery the board turns low-level transducer signals into regulated coil currents and provides status lines to the controller, simplifying closed-loop pressure, force, or position control. The card interfaces directly with valve coils arranged in manifold blocks or standalone actuators used in presses and injection machines.

Electrical integration centers on a nominal bus of 24 VDC, which feeds on-board regulators that generate an auxiliary +15 VDC reference for external electronics. Rack connection uses a DIN 41612 edge with the F48 pin pattern, keeping wiring consistent across cards. The amplifier accepts up to 20 mA of sensor current and tolerates sensor voltages to 24 V; input paths carry 100 Ω and 100 kΩ of resistance respectively to avoid loading transducers. A 47 kΩ enable input and a 2.7 kΩ opto-isolated switch provide logic gating. Setup crews can view output through a 10 kΩ monitor jack without disturbing the circuit.

Supervisory functions shield the drive stage from abnormal conditions. An alarm line can sink 50 mA through a 50 Ω path when voltage or temperature exceeds limits, while an out-of-range output sources 100 mA at 24 VDC to flag excessive feedback error. Both diagnostics occupy the same backplane area, allowing PLC monitoring without extra wiring. Technicians access live valve currents through 2 mm test jacks; the small port saves panel space yet accepts standard probes. These features accelerate troubleshooting and support preventive maintenance on hydraulic axes.

Alarm Output Max Current
50 mA
Alarm Output Resistance
50 Ω
Control Supply Output
+15 VDC
Control Voltage
10.5 to 30 V DC
Current Consumption
Max 2.5 A
Current Inputs
~15V, ~10V with specific maximum current ratings
Edge Connector Standard
DIN 41612
Edge Connector Type
F48
Enable Input Resistance
47 kΩ
Housing Type
Plug-in unit of 3U height (IEC 297)
Input Voltage
24 V DC
Max Sensor Current Input
20 mA
Max Sensor Voltage Input
24 V
Monitor Jack Resistance
10 kΩ
Mounting Type
Plug-in Card (Eurocard)
Nominal Supply Voltage
24 VDC
Nominal Voltage
24V DC, 50W
Opto Switch Input Resistance
2.7 kΩ
Out-of-range Output Max Current
100 mA
Out-of-range Output Nominal
24 VDC
Output Current
Max 2 A
Sensor Current Input Resistance
100 Ω
Sensor Voltage Input Resistance
100 kΩ
Shut-down
Below 18V DC, Reverse-polarity protection
Signal Inputs
Voltage / Current (configurable)
Size (l X W X H)
Approx. 254 mm x 100 mm x 40 mm
Solenoid Current
Max. 3.2A
Test Jack Diameter
2 mm
Voltage Range
20V to 40V (including pk-to-pk ripple up to 10%)
Weight
330g (0.15 lb)
  • eea-pam-561-e-32
  • EEAPAM561E32
  • eeapam561e32
  • EEA-PAM-S61-E-32
  • EEA-PAM-5G1-E-32
  • EEA-PAM-56I-E-32
  • EEA-PAM-561-E-3Z
  • EEA-PAM-SGI-E-3Z
  • EEAPAM-561-E-32
  • EEA-PAM561-E-32
  • EEAPAM561-E-32
  • EEA-PAM-561E-32
  • EEAPAM-561E-32
  • EEA-PAM561E-32
  • EEAPAM561E-32
  • EEA-PAM-561-E32
  • EEAPAM-561-E32
  • EEA-PAM561-E32
  • EEAPAM561-E32
  • EEA-PAM-561E32

Frequently Asked Questions about EEA-PAM-561-E-32:

Q: What is the nominal supply voltage required for the EEA-PAM-561-E-32 power amplifier?

A: The EEA-PAM-561-E-32 amplifier operates at a nominal supply voltage of 24 VDC.

Q: What standard and type of edge connector does the EEA-PAM-561-E-32 use?

A: This model utilizes a DIN 41612 edge connector, type F48, for secure electrical connections.

Q: What is the control supply output voltage offered by the EEA-PAM-561-E-32?

A: +15 VDC control supply output is provided by the EEA-PAM-561-E-32 amplifier for compatible devices.

Q: What is the maximum current for the alarm output on the EEA-PAM-561-E-32?

A: The alarm output on this unit supports a maximum current of 50 mA for signaling applications.

Q: What is the maximum sensor voltage input allowed on the EEA-PAM-561-E-32?

A: A maximum sensor voltage input of 24 V is supported by the EEA-PAM-561-E-32 amplifier.


Internal Product Review

  • ‘‘The EEA-PAM-561-E-32 is a Vickers power amplifier designed for precise electrohydraulic control, featuring a nominal supply voltage of 24 VDC and a control supply output of +15 VDC. The unit utilizes a DIN 41612 F48 edge connector for straightforward integration and offers a 50 mA alarm output for enhanced system monitoring. This model stands out for its reliable performance in demanding industrial automation environments.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo