EEA-PAM-553-A-30 Vickers
Wake Industrial LLC is not an authorized distributor of this product.
The Vickers EEA-PAM-553-A-30 is part of the EEA-PAM Power Amplifiers series and features a nominal supply voltage of 24 VDC with a power consumption of 40 Watts. The control supply output is ±15 VDC with a supply current of 50 mA, and it provides a reference output of ±10 VDC at 5 mA.
Internal Product Review
The EEA-PAM-553-A-30 from Vickers is a high-performance power amplifier designed for precise control in demanding industrial environments. It features a nominal 24 VDC supply voltage with undervoltage shutdown at 18 VDC, ensuring stable operation and reliable protection. With a reference accuracy of ±1% and low supply ripple, this amplifier stands out for dependable signal integrity.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The EEA-PAM-553-A-30 is a plug-in power amplifier card built by Vickers for the EEA-PAM Power Amplifiers series. In hydraulic automation systems it converts ±10 V command references into controlled coil currents for proportional valves, letting a PLC or motion controller adjust fluid flow without direct high-power switching.
The card operates from a nominal supply of 24 VDC and draws up to 40 W. Internal electronics require only 50 mA of control supply current while creating a regulated output of ±15 VDC for external sensors or potentiometers. A separate reference channel delivers ±10 VDC at 5 mA; ripple on this channel is limited to 20 mV pk-pk and its temperature drift stays under 1 mV/°C. Control-supply ripple must remain below 50 mV pk-pk, and the main supply may fluctuate by ±10 % pk-pk without affecting accuracy. The enable circuit presents 22 kΩ of impedance, recognizes OFF when the signal is below 4.5 VDC, and connects to a 10 kΩ monitor output for status feedback.
Total loop error is held within ±1 % of the reference, so commanded spool positions remain predictable. The amplifier becomes active when the enable line reaches 9.8 VDC; if the bus drops to 18 VDC it triggers undervoltage shutdown to protect connected valves. Under normal conditions the design tolerates supply ripple up to ±10 % pk-pk without drifting from set-points. Additional safeguards include reference ripple limits, an enable impedance that prevents loading of logic outputs, and a defined 10 kΩ monitor impedance that keeps diagnostic lines isolated from the control network.