EEA-PAM-525-F-30 Vickers
Wake Industrial LLC is not an authorized distributor of this product.
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The EEA-PAM-525-F-30 is a power amplifier manufactured by Vickers as part of the EEA-PAM Power Amplifiers series. It operates with a 24 VDC power supply, supports a control output supply of +15V for LVDTs, and has mass of 0.4 kilograms. The device allows voltage command input of ±10V at 47 kΩ and a current command input of ±20 mA at 100 Ω.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The EEA-PAM-525-F-30 is a plug-in power amplifier card manufactured by Vickers for the EEA-PAM Power Amplifiers series. Designed for electrohydraulic automation, it conditions analog or current references and drives proportional valve coils so that flow or pressure can be modulated in real time. Its circuitry operates from a single 24 VDC cabinet supply, keeping installation simple while providing internal reference voltages for closed-loop speed and position control. This arrangement lets one compact card support both command processing and valve actuation inside a hydraulic control cabinet.
The card accepts a current command of ±20 mA across a 100 Ω shunt and also processes a voltage command of ±10 V at 47 kΩ input impedance, giving flexibility when paired with PLC analog outputs. An enable window of 17 to 40 V must be present on the logic terminal for the power stage to activate, while a separate disable line is recognized between 0 and 3.5 V to force immediate shutdown. Digital inputs load no more than 10 mA, minimizing the burden on upstream I/O modules. Velocity demand, ramp, and P-controller channels each use ±10 V signals with dedicated impedance levels to shape acceleration and steady-state dynamics. Reference outputs supply ±10 V at 5 mA for potentiometers or external summing nodes. Mass is held to 0.4 kg, allowing the board to mount on light DIN rail carriers without additional supports. Separate control paths also allow the card to fit systems that combine command inputs, ramp generation, and closed-loop correction on one amplifier.
A diagnostic transistor sinks up to 50 mA to announce overcurrent, overtemperature, or external fault conditions to a PLC alarm input. Internal regulators furnish +15 V exclusively for LVDT position transducers, eliminating the need for separate excitation modules. Reliable operation is specified from 0 to 50 °C, and the assembly may be stored or shipped at –25 to +85 °C without performance loss. Ramp and P-controller outputs mirror their respective inputs at ±10 V through paths of 10 kΩ or less, enabling easy signal monitoring during setup. The available fault indication and monitor points support straightforward status observation within the larger control system.
Frequently Asked Questions about EEA-PAM-525-F-30:
Q: What voltage power supply is needed for the EEA-PAM-525-F-30 amplifier?
A: This amplifier requires a 24 VDC power supply for operation.
Q: What is the current command input specification for the EEA-PAM-525-F-30?
A: The current command input supports ±20 mA with a 100 Ω impedance.
Q: What is the operating temperature range for the EEA-PAM-525-F-30?
A: The EEA-PAM-525-F-30 can operate in temperatures from 0 to 50 °C.
Q: What is the control output supply available on the EEA-PAM-525-F-30?
A: +15V supply is provided only for use with LVDTs on this model.
Q: How much does the EEA-PAM-525-F-30 power amplifier weigh?
A: This unit weighs 0.4 kg, making it lightweight for control cabinet integration.