EEA-PAM-525-E-32 Vickers

Ask for Availability

Preparing your secure checkout page...

The Vickers EEA-PAM-525-E-32 is part of the EEA-PAM Power Amplifiers series. It operates with a power supply of 24 V DC at 50 W and a control supply output voltage of +15 V DC. This amplifier features sensor current input up to 20 mA and supports three mode switch positions.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The EEA-PAM-525-E-32 is a plug-in power amplifier card from Vickers in the EEA-PAM Power Amplifiers series. It is intended for mounting in a standardized Eurocard rack where it modulates current to proportional hydraulic valves and forwards status signals to supervisory controls, giving machine builders a compact interface between low-level electronics and high-power electrohydraulic actuators.

The board draws a nominal supply of 24 V DC × 50 W, covering both logic and solenoid drive needs, while an auxiliary rail delivers +15 V DC for external sensors. Alarm circuitry can source up to 50 mA through a 50 Ω internal resistor so the host controller can detect fault conditions without a relay. When a command or sensor exceeds calibrated limits an out-of-range line supplies 100 mA at 24 V DC to trigger machine interlocks. The card accepts a maximum sensor current of 20 mA via a 100 Ω input so 4–20 mA transmitters can be read directly, and a voltage input up to +24 V is accepted against a 100 kΩ impedance to minimize loading. Three mode-selector positions let technicians switch among normal, ramp-test, and override functions for commissioning.

A digital enable channel operates at 24 V DC and is filtered by 2.7 kΩ input resistance, while a separate readiness input uses 47 kΩ to prevent false starts from line noise. For diagnostics, the monitor point is buffered through a 10 kΩ resistor and presented on a 2.0 mm socket so system current or valve command voltage can be viewed with a multimeter. Additional terminals provide a 50 Ω alarm return, confirm that sensor voltage never surpasses +24 V, and extend a 100 mA out-of-range sink so multiple safety devices can be wired in parallel without external splitters.

Alarm Output Max Current
50 mA
Alarm Output Resistance
50 Ω
Control Supply Output Voltage
+15 V DC
Current Output
~50 mA
Digital Input Nominal Voltage
24 V DC
Digital Input Resistance
2.7 kΩ
Dimensions
50 mm (W) x 270 mm (D) x 180 mm (H)
Enable Input Resistance
47 kΩ
Feedback Type
LVDT
Input Impedance (voltage)
~47k?
Input Signal
~10 V or 4...20 mA
Input Voltage
24 VDC
Mode Switch Positions
3
Monitor Point Output Resistance
10 kΩ
Monitor Point Socket Diameter
2.0 mm
Mounting
DIN rail or rack
Out-of-range Output Max Current
100 mA
Out-of-range Output Nominal
24 V DC
Output Voltage For Valve
~15 V
Power Consumption
Max 18 VA
Power Supply Nominal
24 V DC x 50 W
Protection Class
IP20
Ramp Function
Switchable, 50ms-5s
Sensor Current Input Max
20 mA
Sensor Current Input Resistance
100 Ω
Sensor Voltage Input Max
+24 V
Sensor Voltage Input Resistance
100 kΩ
Signal Connector
Screw terminals
Temperature Range
0...+50 degrees C (operating)
Type
Servo Amplifier
Weight
Approx. 1.2 kg
  • eea-pam-525-e-32
  • EEAPAM525E32
  • eeapam525e32
  • EEA-PAM-S25-E-32
  • EEA-PAM-5Z5-E-32
  • EEA-PAM-52S-E-32
  • EEA-PAM-525-E-3Z
  • EEA-PAM-SZS-E-3Z
  • EEAPAM-525-E-32
  • EEA-PAM525-E-32
  • EEAPAM525-E-32
  • EEA-PAM-525E-32
  • EEAPAM-525E-32
  • EEA-PAM525E-32
  • EEAPAM525E-32
  • EEA-PAM-525-E32
  • EEAPAM-525-E32
  • EEA-PAM525-E32
  • EEAPAM525-E32
  • EEA-PAM-525E32

Frequently Asked Questions about EEA-PAM-525-E-32:

Q: What is the nominal power supply specification for the EEA-PAM-525-E-32 amplifier?

A: The EEA-PAM-525-E-32 features a power supply rated at 24 V DC and 50 W.

Q: What is the nominal digital input voltage required for the EEA-PAM-525-E-32?

A: The digital input voltage for this amplifier is 24 V DC.

Q: How many mode switch positions are present on the EEA-PAM-525-E-32?

A: This model offers three distinct mode switch positions for operational flexibility.

Q: What is the maximum current rating for the alarm output on the EEA-PAM-525-E-32?

A: The alarm output on this amplifier can provide a maximum current of 50 mA.

Q: What is the maximum sensor current input supported by the EEA-PAM-525-E-32?

A: The sensor current input for this amplifier is rated at a maximum of 20 mA.


Internal Product Review

  • ‘‘The EEA-PAM-525-E-32 power amplifier from Vickers features a 24 V DC power supply with 50 W capacity, making it suitable for demanding industrial environments. It offers three mode switch positions and a +15 V DC control supply output, supporting flexible system integration. This amplifier stands out for its reliable performance and versatile control options.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo