The Vickers EEA-PAM-525-D-32 is a power amplifier from the EEA-PAM Power Amplifiers series. It operates with a supply voltage of 24 VDC and features a control supply output voltage of +15 V. The amplifier has an alarm output resistance of 50 ohms and a maximum digital output load current of 100 mA.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The EEA-PAM-525-D-32 is a plug-in power amplifier card manufactured by Vickers for the EEA-PAM Power Amplifiers series. Installed in hydraulic control racks, the card converts low-level electrical references from a PLC or analog loop into proportional solenoid current so that directional or pressure valves follow commanded flow or force profiles in automated machinery. By integrating signal conditioning, ramp generation, PID control, and alarm functions on one board, the module simplifies panel wiring and preserves response consistency.
The board operates from a nominal supply of 24 VDC, while its internal regulator distributes a stabilized output of +15 V for external sensors or potentiometers. Alarm circuitry can sink up to 50 mA, and the fault line is limited by an alarm output resistance of 50 Ω so downstream indicators are protected against short circuits. Command accuracy depends on signal loading: the voltage command input presents 47 kΩ, the separate current command path shows 100 Ω, and the feed-forward node offers a moderate 6 kΩ impedance that permits velocity-type pre-control without upsetting the main loop. Reference output current is fixed at 5 mA to bias potentiometric setpoints, and the ramp generator accepts sources that see 10 kΩ.
Feedback and diagnostic links are arranged to avoid loading sensitive circuits. The monitor point is buffered by a 10 kΩ impedance so oscilloscopes or panel meters do not affect loop tuning, and the PID stage will drive loads of 10 kΩ without saturation. A ramp-active indicator shares the same 10 kΩ resistance value to keep LED current predictable. Sensor channels are split: the current input is matched to 100 Ω, while the voltage input reaches 1 MΩ to minimize leakage from bridge transducers. Digital outputs can supply up to 100 mA for relays or lamps provided the connected device exceeds the required pull-up resistance of 5 kΩ. Together these limits define the permissible cabling lengths and ensure stable electrohydraulic actuation.
Frequently Asked Questions about EEA-PAM-525-D-32:
Q: What supply voltage does the EEA-PAM-525-D-32 require?
A: The EEA-PAM-525-D-32 operates with a supply voltage of 24 VDC.
Q: What is the control supply output voltage available on the EEA-PAM-525-D-32?
A: This amplifier provides a control supply output voltage of +15 V for powering connected components.
Q: What is the maximum digital output load current supported by the EEA-PAM-525-D-32?
A: The maximum digital output load current for this power amplifier is 100 mA.
Q: What are the alarm output specifications on the EEA-PAM-525-D-32?
A: For alarm output, the maximum current available is 50 mA with an output resistance of 50 Ω.
Q: What is the input impedance of the voltage command input on the EEA-PAM-525-D-32?
A: The voltage command input on this amplifier features an input impedance of 47 kΩ.