EEA-PAM-118-A-30 Vickers

The Vickers EEA-PAM-118-A-30 is a power amplifier from the EEA-PAM Power Amplifiers series. It features a Eurocard format and supports both voltage and current input signal types, using pulse width modulation. This cabinet-mounted unit has a supply voltage of 24 VDC, switchable ramp function, and automatic overload reset.

No Hidden Fees Rush or Credit Card
No Tariffs On US Orders

Internal Product Review

The EEA-PAM-118-A-30 is a Vickers power amplifier with a Eurocard format. Voltage and current input support combined with pulse width modulation delivers precise, responsive control in electrohydraulic circuits. Automatic overload reset and a switchable ramp function add practical tuning and dependable recovery, making this amplifier a strong choice for demanding control applications.

Sell Part Have a part to sell?
Warranty Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The EEA-PAM-118-A-30 is a power amplifier card produced by Vickers for the EEA-PAM Power Amplifiers series. It conditions command signals from programmable controllers and delivers regulated coil current to proportional hydraulic valves, allowing precise closed-loop motion or pressure control in industrial automation. The board’s Eurocard outline permits quick insertion into standard 19-inch racks, so multiple axes can be managed within the same cabinet.

This model conforms to the Eurocard format, which simplifies service because the card can be removed from a rack instead of being hard-wired into place. Incoming reference channels accept both voltage and current signals, letting the same card interpret 0–10 V or 4–20 mA commands without external converters. Output energy is modulated by Pulse Width Modulation (PWM), so changing duty cycle alters average coil current while keeping switching losses low. The card receives its control power from a single 24 VDC supply, reducing wiring complexity compared with multi-rail arrangements. For enclosure layout, the unit is intended for cabinet-mounted installation, so cooling airflow and noise-immunity planning assume placement on a backplane inside a sealed panel. User-facing monitoring points built into the front edge connector provide convenient oscilloscope access for setup and diagnostics.

An internal protection circuit trips during excessive load demand and recovers through an automatic reset, eliminating manual fuse replacement after short-term faults. Acceleration and deceleration profiles are shaped by a switchable ramp generator that can be enabled when gradual valve movement is needed to prevent hydraulic shock. Physical depth is 7.000 in, and front width is 1.590 in, so multiple amplifiers can fit side by side while leaving airflow gaps. The height is 5.000 in, which matches standard rack slots and preserves access to the user monitoring points on the front edge.

Amplifier Type
Power Amplifier
Card Format
Eurocard
Input Signal Type
Voltage And Current
Modulation Method
Pulse Width Modulation (PWM)
Monitoring Points
User-Facing
Mounting Style
Cabinet-Mounted
Overload Reset
Automatic Reset
Product Height
5.000 in
Product Length
7.000 in
Product Width
1.590 in
Ramp Function
Switchable
Supply Voltage
24 VDC

Frequently Asked Questions about EEA-PAM-118-A-30:

Q: What types of input signals does the EEA-PAM-118-A-30 support?

A: The EEA-PAM-118-A-30 power amplifier accepts both voltage and current input signals for flexible control options.

Q: What modulation method is implemented in the EEA-PAM-118-A-30?

A: This model uses a pulse width modulation (PWM) method for signal modulation.

Q: How does the EEA-PAM-118-A-30 handle overload reset?

A: The EEA-PAM-118-A-30 features an automatic overload reset, eliminating the need for manual intervention if overload occurs.

Q: Does the EEA-PAM-118-A-30 offer user-facing monitoring points?

A: User-facing monitoring points allow for direct access and observation of performance values on the EEA-PAM-118-A-30.

Q: What supply voltage is required for the EEA-PAM-118-A-30 power amplifier?

A: This amplifier operates on a supply voltage of 24 VDC, suitable for common industrial control systems.

Symptom / card indication Likely cause First troubleshooting steps
No green “PWR” LED 24 V DC supply absent or < 18 V Measure supply at pins a/b; restore regulated 24 V DC and verify fuse F1.
Red “UV” (undervoltage) LED lit Supply dip during solenoid energizing Check cabinet PSU size, look for loose field-wiring terminals, monitor inrush current.
Valve strokes fully when command = 0 V Dead-band pots not set / offset drift Center the valve, adjust “Z” (zero) trimmer until flow stops, then fine-tune per manual.
Output current saturates at 100 % Gain too high or feedback loop open Reduce “G” gain pot, inspect LVDT / spool-position feedback wiring.
Oscillation / valve chatter Insufficient damping or wiring noise Add 0.1 µF snubbers across coils, separate power and feedback cables, increase ramp time.
“PK” peak/hold LED never goes off Peak-current timer set too long Reset “TP” peak-time trimmer to nominal 60 ms; confirm spool now moves smoothly.
Command signal present, no coil current Enable (pin d1) missing or logic low Supply +24 V to enable pin; verify safety/PLC interlock contacts.
Only one solenoid drives A/B channel link wires mis-set Check D-sub links d18–d20; set per single/dual-solenoid valve type.
Ramp time pot has no effect Ramp generator disabled by jumper Inspect link d14; reinstall to activate internal ramp module.
Card runs hot (> 55 °C) Shorted coil or over-current Measure coil Ω; compare to valve spec, replace damaged coil or lower max-gain.
Model Valve family / application Supply V DC Max output current Ramp adj. range
EEA-PAM-118-A-30 KDG4V-2/3 single-solenoid throttle 24 V 1.6 A 0.05 – 5 s
EEA-PAM-118-A-10 Same as above, early -10 design 24 V 1.6 A 0.05 – 2 s
EEA-PAM-113-A-30 KTG4V-3 dir-control valves 24 V 2:00 AM 0.05 – 5 s
EEA-PAM-115-A-30 KDG5V-5 throttle (higher flow) 24 V 3:00 AM 0.05 – 5 s
EEA-PAM-511-A-30 ECG-02 pressure valves 24 V 0–20 mA (dual) 0.05 – 5 s
EEA-PAM-523-A-32 KDG4V-3 & KDG5V-5 (dual-coil) 24 V ±20 mA 0.05 – 10 s
Indicator / “error code” What it means
24 V PWR LED off No or low card supply voltage
+15 V control LED off Internal control rail missing
Overload LED red Coil/output over-current detected
LVDT Fail LED red Feedback loop open / sensor fault
Low-voltage trip (< 19 V) Card undervoltage protection active
Enable LED (yellow) dark 24 V logic “Output Enable” absent
Output-level bar stuck high Solenoid current saturated / shorted
Dead-band pot mis-set Valve drifts at 0 V command
Gain pot too high Instability or valve chatter
Ramp link disabled (b12-b20 jumpered) No accel/decel ramp applied